Do you have a question about the Mitsubishi Electric PUY-A42NKA7 and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | PUY-A42NKA7 |
Category | Air Conditioner |
Language | English |
Guidelines for safe operation and maintenance procedures.
Table detailing refrigerant charge amounts for various piping lengths.
Standard operation data for heat pump models.
Wiring diagram for PUZ-A12/18NKA7 and PUY-A12/18NKA7 series outdoor units.
Wiring diagram for PUZ-A24/30NHA7 and PUY-A24/30NHA7 series outdoor units.
Wiring diagram for PUZ-A36/42NKA7 and PUY-A36/42NKA7 series outdoor units.
Refrigerant system diagram for PUZ-A12/18NKA7 series outdoor units.
Refrigerant system diagram for PUY-A12/18NKA7 series outdoor units.
Refrigerant system diagram for PUZ-A24/30NHA7 and PUZ-A36/42NKA7 series.
Refrigerant system diagram for PUY-A24/30NHA7 and PUY-A36/42NKA7 series.
Table summarizing check codes and actions for reoccurring and non-reoccurring troubles.
Pre-test run checks including leak detection, impedance measurement, and switch settings.
Procedure for performing test run operations using the wired remote controller.
Procedure for checking and resetting error information displayed on the remote controller.
Method to view error information and history from the main menu.
Procedure to view and delete error history records.
Steps to delete error history from the check menu.
Procedure for performing test run using an IR wireless remote controller.
Steps for performing self-diagnosis using the wired remote controller.
Procedure for resetting error history after self-diagnosis.
Procedure for checking the remote controller's functionality.
List of abnormalities detected during unit operation with troubleshooting steps.
Troubleshooting for high pressure switch activation during compressor operation.
Troubleshooting for high discharge or high compressor surface temperatures.
Troubleshooting for open/short circuits in TH4 and TH33 thermistors.
Troubleshooting for open/short circuits in various outdoor unit thermistors.
Troubleshooting for abnormal heat sink temperatures detected by TH8.
Troubleshooting for power module abnormalities like overcurrent.
Troubleshooting for abnormal rotational frequency of the outdoor DC fan motor.
Troubleshooting for overvoltage errors related to DC bus voltage.
Troubleshooting for undervoltage errors related to DC bus voltage.
Troubleshooting for errors related to low input current.
Troubleshooting for abnormal power synchronous signals.
Troubleshooting for PFC errors including over/undervoltage and overcurrent.
Troubleshooting for compressor overcurrent interruption when locked.
Troubleshooting for current sensor errors.
Troubleshooting for low pressure conditions during heating or cooling.
Troubleshooting for compressor overcurrent interruption after startup.
Troubleshooting remote controller transmission and signal receiving errors.
Troubleshooting for abnormalities in the remote controller control board.
Troubleshooting remote controller transmission and signal receiving errors.
Troubleshooting indoor/outdoor unit communication errors (signal receiving).
Troubleshooting indoor/outdoor unit communication errors (transmitting).
Troubleshooting remote controller signal receiving errors detected by the remote controller.
Troubleshooting remote controller transmitting errors detected by the remote controller.
Troubleshooting remote controller signal receiving errors detected by the indoor unit.
Troubleshooting remote controller transmitting errors detected by the indoor unit.
Troubleshooting for abnormal refrigerant circuit conditions.
Troubleshooting signal receiving errors in outdoor unit communication.
Troubleshooting transmitting errors in outdoor unit communication.
Troubleshooting serial communication errors between boards.
Troubleshooting communication issues between controller and M-NET boards.
Troubleshooting abnormal pipe temperatures in cooling and heating modes.
Categories for M-NET communication errors.
Troubleshooting errors caused by duplicate controller addresses in M-NET communication.
Troubleshooting NO ACK signals in M-NET communication.
Troubleshooting M-NET NO RESPONSE errors.
Troubleshooting steps when the remote controller display is not working.
Table of check codes, LED indicators, and inspection methods for abnormal conditions.