Cooling Capacity | 2.5 kW |
---|---|
Heating Capacity | 3.2 kW |
Power Supply | 220-240V, 50Hz |
Refrigerant | R32 |
Outdoor Unit Dimensions (HxWxD) | 550 x 800 x 285 mm |
Outdoor Unit Weight | 35 kg |
Illustrates the physical parts and airflow pathways of the indoor unit.
Details the function of each button on the wired remote controller.
Explains the various indicators and displays on the wired remote controller.
Provides important notes and warnings regarding the use of the wired remote controller.
Noise performance data for SEZ-KD25VAQ at 5Pa external static pressure.
Noise performance data for SEZ-KD25VAQ at 15Pa external static pressure.
Noise performance data for SEZ-KD25VAQ at 35Pa external static pressure.
Noise performance data for SEZ-KD25VAQ at 50Pa external static pressure.
Noise performance data for SEZ-KD35VAQ at 5Pa external static pressure.
Noise performance data for SEZ-KD35VAQ at 15Pa external static pressure.
Noise performance data for SEZ-KD35VAQ at 35Pa external static pressure.
Noise performance data for SEZ-KD35VAQ at 50Pa external static pressure.
Noise performance data for SEZ-KD50VAQ at 5Pa external static pressure.
Noise performance data for SEZ-KD50VAQ at 15Pa external static pressure.
Noise performance data for SEZ-KD50VAQ at 35Pa external static pressure.
Noise performance data for SEZ-KD50VAQ at 50Pa external static pressure.
Noise performance data for SEZ-KD60VAQ at 5Pa external static pressure.
Noise performance data for SEZ-KD60VAQ at 15Pa external static pressure.
Noise performance data for SEZ-KD60VAQ at 35Pa external static pressure.
Noise performance data for SEZ-KD60VAQ at 50Pa external static pressure.
Noise performance data for SEZ-KD71VAQ at 5Pa external static pressure.
Noise performance data for SEZ-KD71VAQ at 15Pa external static pressure.
Noise performance data for SEZ-KD71VAQ at 35Pa external static pressure.
Noise performance data for SEZ-KD71VAQ at 50Pa external static pressure.
Fan performance curves for SEZ-KD25VAQ at 5Pa external static pressure.
Fan performance curves for SEZ-KD25VAQ at 15Pa external static pressure.
Fan performance curves for SEZ-KD25VAQ at 35Pa external static pressure.
Fan performance curves for SEZ-KD25VAQ at 50Pa external static pressure.
Fan performance curves for SEZ-KD35VAQ at 5Pa external static pressure.
Fan performance curves for SEZ-KD35VAQ at 15Pa external static pressure.
Fan performance curves for SEZ-KD35VAQ at 35Pa external static pressure.
Fan performance curves for SEZ-KD35VAQ at 50Pa external static pressure.
Fan performance curves for SEZ-KD50VAQ at 5Pa external static pressure.
Fan performance curves for SEZ-KD50VAQ at 15Pa external static pressure.
Fan performance curves for SEZ-KD50VAQ at 35Pa external static pressure.
Fan performance curves for SEZ-KD50VAQ at 50Pa external static pressure.
Fan performance curves for SEZ-KD60VAQ at 5Pa external static pressure.
Fan performance curves for SEZ-KD60VAQ at 15Pa external static pressure.
Fan performance curves for SEZ-KD60VAQ at 35Pa external static pressure.
Fan performance curves for SEZ-KD60VAQ at 50Pa external static pressure.
Fan performance curves for SEZ-KD71VAQ at 5Pa external static pressure.
Fan performance curves for SEZ-KD71VAQ at 15Pa external static pressure.
Fan performance curves for SEZ-KD71VAQ at 35Pa external static pressure.
Fan performance curves for SEZ-KD71VAQ at 50Pa external static pressure.
Illustrates the overall dimensions and connection points of the indoor unit.
Presents various configurations for creating maintenance access spaces around the unit.
Detailed schematic of the internal wiring and components of the control box.
Diagram showing refrigerant path in cooling and heating modes.
Safety precautions, general checks, and using the self-check function for diagnostics.
Diagnosing problems with the wired remote controller and understanding its LED indicators.
Procedure for conducting a test run with the wireless remote controller.
Lists error codes and symptoms detected by indoor and outdoor units for troubleshooting.
Detailed table linking error codes to abnormal points, causes, and countermeasures.
Troubleshooting steps when LED2 on the indoor controller board is off or blinking.
Diagram showing specific test points and their voltage references on the board.
Criteria for checking thermistors and motor component functionality.
Step-by-step guide to diagnose issues with the DC fan motor.
Steps to remove and access the control box components.
Procedure for removing the intake air thermistor.
Steps to remove the drainpan and air filter.
Procedure for removing the condenser/evaporator thermistor.
Steps for removing the fan casing, motor cable, fan motor, and Sirocco fan.
Procedure for removing the bearing assembly on specific models.
Steps for removing the heat exchanger unit.