EasyManua.ls Logo

Mitsubishi Heavy Industries FDC100VNA-W User Manual

Mitsubishi Heavy Industries FDC100VNA-W
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
(Split system, air to air heat pump type)
DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE
Single type
FDUM100VNAWVH
100VSAWVH
125VNAWVH
125VSAWVH
140VNAWVH
140VSAWVH
Twin type
FDUM100VNAWPVH
100VSAWPVH
125VNAWPVH
125VSAWPVH
140VNAWPVH
140VSAWPVH
Triple type
FDUM140VNAWTVH
140VSAWTVH
CEILING CASSETTE-4 WAY COMPACT TYPE
Twin type
FDTC100VNAWPVH
100VSAWPVH
125VNAWPVH
125VSAWPVH
Single type
FDT100VNAWVH
100VSAWVH
125VNAWVH
125VSAWVH
140VNAWVH
140VSAWVH
CEILING CASSETTE-4 WAY TYPE
Twin type
FDT100VNAWPVH
100VSAWPVH
125VNAWPVH
125VSAWPVH
140VNAWPVH
140VSAWPVH
Triple type
FDT140VNAWTVH
140VSAWTVH
Triple type
FDTC140VNAWTVH
140VSAWTVH
MICRO INVERTER PACKAGED AIR-CONDITIONERS
Single type
SRK100VNAWZR
100VSAWZR
WALL MOUNTED TYPE
Twin type
SRK100VNAWPZSX
100VSAWPZSX
125VNAWPZSX
125VSAWPZSX
140VNAWPZR
140VSAWPZR
Triple type
SRK140VNAWTZSX
140VSAWTZSX
DUCT CONNECTED-HIGH STATIC PRESSURE TYPE
Single type
FDU100VNAWVH
100VSAWVH
125VNAWVH
125VSAWVH
140VNAWVH
140VSAWVH
(OUTDOOR UNIT)
FDC100VNA-W
100VSA-W
125VNA-W
125VSA-W
140VNA-W
140VSA-W
(INDOOR UNIT)
FDT50VH
60VH
71VH
FDE50VH
60VH
71VH
V Multi System
Single type
FDE100VNAWVH
100VSAWVH
125VNAWVH
125VSAWVH
140VNAVWH
140VSAVWH
Twin type
FDE100VNAWPVH
100VSAWPVH
125VNAWPVH
125VSAWPVH
140VNAWPVH
140VSAWPVH
CEILING SUSPENDED TYPE
Triple type
FDE140VNAWTVH
140VSAWTVH
Manual No.'19 • PAC-SM-309
SERVICE MANUAL
updated January 27, 2020

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDC100VNA-W and is the answer not in the manual?

Mitsubishi Heavy Industries FDC100VNA-W Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDC100VNA-W
CategoryAir Conditioner
LanguageEnglish

Summary

MICRO INVERTER PACKAGED AIR-CONDITIONERS

V Multi System Overview

Details on operation, maintenance, disassembly, wiring, and piping for V Multi systems.

1. MICRO INVERTER PACKAGED AIR-CONDITIONERS

Microcomputer Operation Control

Details operation control functions managed by microcomputers, including remote and indoor controls.

Wired Remote Control Operation

Functions and operations controlled via wired remote control models like RC-EX3A and RC-E5.

Indoor Unit Control Functions

Covers operation control by indoor units for FDT, FDTC, FDU, FDUM, FDE series, including auto operation and timer functions.

Outdoor Unit Control Functions

Explains operation control functions managed by the outdoor unit, including compressor speed and fan control.

Maintenance and Troubleshooting Data

Provides maintenance data, diagnostic functions, and troubleshooting flows for microcomputer circuits.

Disassembly Procedures

Step-by-step instructions for disassembling indoor and outdoor units for maintenance and repair.

Electrical Wiring Diagrams

Provides wiring diagrams for indoor and outdoor units, covering various types like ceiling cassette and wall mounted.

Piping System Configurations

Illustrates piping layouts for single, twin, and triple type systems, including sensor and valve locations.

2. V MULTI SYSTEM

V Multi System Operation Control

Overview of operation control by microcomputer for V Multi systems.

V Multi System Maintenance Data

Contains maintenance data for the V Multi system.

V Multi System Disassembly

Procedure for disassembling V Multi system components.

V Multi System Electrical Wiring

Electrical wiring diagrams for the V Multi system.

V Multi System Piping

Piping system diagrams for the V Multi system.

Related product manuals