EasyManua.ls Logo

Mitsubishi Heavy Industries FDC306HEN3 User Manual

Mitsubishi Heavy Industries FDC306HEN3
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FDT 8/8 Cassette Performance and Engineering data Page 1
FDT 8/6 Cassette Performance and Engineering data Page 2
FDT Cassette Installation Page 3
FDT Cassette Space Collars Page 5
FDT Cassette Engineering drawings Page 6
Remote Control RCD Wired controller Page 9
RCD Group Control and set up Page 10
Operation, Error Codes Page 11
FDEN 8/8 Ceiling Performance and Engineering data Page 12
FDEN 8/6 Ceiling Performance and Engineering data Page 13
FDEN Ceiling Installation Page 14
FDEN Ceiling Engineering drawings Page 15
FDKN 8/8,6 Wall Performance and Engineering data Page 17
FDKN Wall Installation Page 18
FDKN Wall Engineering drawings Page 19
Remote Control Infra-red Controller Page 22
Refrigerant Pipework Installation Page 23
Low Ambient Control Installation Page 24
Electrical Site Wiring Installation Page 25
Time Clock/BMS Adaptor Wiring adaptor to CnT connection Page 25
SCADE Superlynk adaptor Page 26
Condensate Drains Installation Page 27
FDC Outdoor Units Installation Page 29
FDC Outdoor Units Engineering Drawings Page 31
Multi Systems Specification & Installation Page 38
Safety Information Back Cover
FD 8 Series Split Systems
CONTENTS
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDC306HEN3 and is the answer not in the manual?

Mitsubishi Heavy Industries FDC306HEN3 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDC306HEN3
CategoryAir Conditioner
LanguageEnglish

Summary

Technical Data: FDT 8 Series Cassette and FDC 8 Series Outdoor Units

Technical Data: FDT 8 Series Cassette and FDC 6 Series Outdoor Units

FDT 8 Series Cassette Indoor Unit Specs

Technical specifications for FDT 8 Series cassette indoor units, including dimensions and fan data.

Installation of FDT Cassette Units

Unit Location

Guidance on selecting an optimal location for air distribution and avoiding drafts.

Installation Space

Specifies required clearances and dimensions for unit installation.

Condensate Piping

Details on condensate lift pump capabilities and piping installation requirements.

FDT Cassette Installation Details

Wired Remote Control Installation

Guidance on installing the RCD wired remote control.

Wireless Infra-Red Remote Control

Details on the wireless infra-red remote control and its bracket.

FDT Cassette 208 Unit Dimensions

FDT Cassette 258/308 Unit Dimensions

FDT Cassette 408/508 Unit Dimensions

Unit Layout and Dimensions

Diagrams showing the layout and dimensions of FDT Cassette 408/508 units.

RCD Wired Remote Control: Installation, Wiring & Setting

RCD Installation Procedures

Steps for physically installing the RCD wired remote control unit.

Master / Slave Control Configuration

Setting up master/slave configurations for multiple controllers.

RCD Wired Remote Control: Group Control and Timers

Group Control Functionality

Using the RCD as a Group Control for up to 16 units.

RCD Wired Remote Control Functions

Fault Diagnosis Codes

List and explanation of error codes for fault diagnosis.

Technical Data: FDEN 8 Series Ceiling and FDC 8 Series Outdoor Units

FDC 8 Series Outdoor Unit Specs

Technical specifications for FDC 8 Series outdoor units.

Technical Data: FDEN 8 Series Ceiling and FDC 6 Series Outdoor Units

FDEN 8 Series Ceiling Indoor Unit Specs

Technical specifications for FDEN 8 Series ceiling indoor units.

FDC 6 Series Outdoor Unit Specs

Technical specifications for FDC 6 Series outdoor units.

Installation of FDEN Ceiling Suspended Units

FDEN Ceiling Suspended Unit Dimensions (208-508)

FDEN Ceiling Suspended Unit Dimensions (408H-508H)

Technical Data: FDKN 8 Series Cassette and FDC 6/8 Series Outdoor Units

FDKN 8 Series Cassette Indoor Unit Specs

Technical specifications for FDKN 8 Series cassette indoor units.

FDC 6/8 Series Outdoor Unit Specs

Technical specifications for FDC 6 and 8 Series outdoor units.

Refrigerant Piping

Information on refrigerant pipe termination sizes and maximum pipe run.

Installation of FDKN Wall Mounted Units

Preparation for Installation

Steps for preparing the wall and mounting plate for FDKN units.

FDKN Wall Mounted Unit Dimensions (FDKN208H)

FDKN Wall Mounted Unit Dimensions (FDKN258H)

FDKN Wall Mounted Unit Dimensions (FDKN308H)

Installation and Service Space

Required clearances for installation and maintenance of FDKN308H unit.

Remote Control (Wireless Infra-Red)

Refrigeration Pipework Installation

Flared Joints and Pressure Testing

Procedures for making flared joints and performing pressure tests.

Refrigerant Charging and System Evacuation

Vacuum Pump and Evacuation Procedure

Steps for evacuating the system using a vacuum pump.

Refrigerant Charging and Weighing

Correct procedure for charging refrigerant using electronic scales.

Electrical Site Wiring and Connections

Condensate Drains Installation and Recommendations

Installation of FDC Outdoor Units

FDC Outdoor Unit Dimensions (206/256 Series)

FDC Outdoor Unit Dimensions (306 Series)

FDC Outdoor Unit Dimensions (406/506 Series)

FDC Outdoor Unit Dimensions (FDC208 Series)

FDC Outdoor Unit Dimensions (258/308 Series)

FDC Outdoor Unit Dimensions (408/508 Series)

FDC Outdoor Unit Dimensions (808/1008 Series)

FD Multi Systems - 8 Series

General Safety Precautions

Electrical Safety Warnings

Crucial warnings regarding electrical installation and shock prevention.

General Cautionary Notes

Important cautions related to building structure, environment, and noise.

Related product manuals