EasyManua.ls Logo

Mitsubishi Heavy Industries FDK28KXZE1 User Manual

Mitsubishi Heavy Industries FDK28KXZE1
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL MANUAL
Manual No.'19 • KX-T-310D
Note:
(INDOOR UNIT)
VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS
Duct connected-High
static pressure type
compact type
Ceiling cassette-4 way type
FDT28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
112KXZE1
140KXZE1
160KXZE1
Wall mounted type
FDK15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
FDE36KXZE1
45KXZE1
56KXZE1
71KXZE1
112KXZE1
140KXZE1
Ceiling cassette-4 way
FDTC15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
Ceiling cassette-2 way type
FDTW28KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
Ceiling cassette-1 way type
FDTS45KXE6F
71KXE6F
Ceiling suspended type
FDU650FKXZE1
1100FKXZE1
1800FKXZE1
2400FKXZE1
Outdoor air processing unit
FDU45KXE6F
Duct connected (thin)-Low
static pressure type
FDUT71KXE6F-E
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
224KXZE1
280KXZE1
Duct connected-Low/Middle
static pressure type
FDUM22KXE6F
28KXE6F
36KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
(1) This document describes the indoor units with service code /F (with motion sensor system
function).
DRAFT

Questions and Answers:

Mitsubishi Heavy Industries FDK28KXZE1 Specifications

General IconGeneral
Cooling Capacity2.8 kW
Heating Capacity3.2 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Indoor Unit Dimensions (W x H x D)845 x 270 x 228 mm
Outdoor Unit Dimensions (W x H x D)780(+62) x 540 x 290(+59) mm
Energy Efficiency Class CoolingA++
Energy Efficiency Class HeatingA+
TypeSplit System
Energy Efficiency Ratio (EER)3.5
Energy Efficiency Ratio (Cooling)3.5

Summary

Specifications

FDT Ceiling Cassette-4 Way Type Specifications

Detailed specifications for FDT series ceiling cassette-4 way indoor units, including capacities, power, noise, and dimensions.

FDTC Ceiling Cassette-4 Way Compact Type Specifications

Detailed specifications for FDTC series ceiling cassette-4 way compact indoor units, including capacities, power, noise, and dimensions.

FDTW Ceiling Cassette-2 Way Type Specifications

Detailed specifications for FDTW series ceiling cassette-2 way indoor units, including capacities, power, noise, and dimensions.

FDTS Ceiling Cassette-1 Way Type Specifications

Detailed specifications for FDTS series ceiling cassette-1 way indoor units, including capacities, power, noise, and dimensions.

FDU Duct Connected-High Static Pressure Type Specifications

Detailed specifications for FDU high static pressure duct connected indoor units, including capacities, power, and dimensions.

FDUM Duct Connected-Low/Middle Static Pressure Type Specifications

Detailed specifications for FDUM low/middle static pressure duct connected indoor units, including capacities, power, and dimensions.

FDUT Duct Connected (thin)-Low Static Pressure Type Specifications

Detailed specifications for FDUT thin low static pressure duct connected indoor units, including capacities and power.

FDK Wall Mounted Type Specifications

Detailed specifications for FDK wall mounted indoor units, including capacities, power, noise, and dimensions.

FDE Ceiling Suspended Type Specifications

Detailed specifications for FDE ceiling suspended indoor units, including capacities, power, and noise level.

FDU-F Outdoor Air Processing Unit Specifications

Detailed specifications for FDU-F outdoor air processing units, including capacities, power, and sound power level.

Exterior Dimensions

Indoor Unit Exterior Dimensions

Provides detailed diagrams and dimensions for various indoor unit types including ceiling cassette, duct connected, wall mounted, and suspended units.

Fan Unit Replacement Procedure

FDU/FDUM Series Fan Unit Replacement

Step-by-step instructions for removing and taking out the fan unit from FDU and FDUM series indoor units.

Remote Control (Option Parts)

RC-EX3A Wired Remote Control Installation

Details dimensions, installation space, and mounting specifications for the RC-EX3A wired remote control.

RCN-E2 Wireless Remote Control Installation

Provides dimensions and installation space for the RCN-E2 wireless remote control.

Electrical Wiring

FDT Ceiling Cassette-4 Way Type Electrical Wiring

Provides wiring diagrams and notes for all FDT models, detailing connections to PCB and components.

FDTC Ceiling Cassette-4 Way Compact Type Electrical Wiring

Provides wiring diagrams and notes for all FDTC models, detailing connections to PCB and components.

FDTW Ceiling Cassette-2 Way Type Electrical Wiring

Provides wiring diagrams and notes for all FDTW models, detailing connections to PCB and components.

FDTS Ceiling Cassette-1 Way Type Electrical Wiring

Provides wiring diagrams and notes for all FDTS models, detailing connections to PCB and components.

FDU Duct Connected-High Static Pressure Type Electrical Wiring

Provides wiring diagrams and notes for FDU models, detailing connections to PCB and components.

FDUM Duct Connected-Low/Middle Static Pressure Type Electrical Wiring

Provides wiring diagrams and notes for FDUM models, detailing connections to PCB and components.

FDUT Duct Connected (thin)-Low Static Pressure Type Electrical Wiring

Provides wiring diagrams and notes for FDUT models, detailing connections to PCB and components.

FDK Wall Mounted Type Electrical Wiring

Provides wiring diagrams and notes for FDK models, detailing connections to PCB and components.

FDE Ceiling Suspended Type Electrical Wiring

Provides wiring diagrams and notes for FDE models, detailing connections to PCB and components.

Noise Level

FDT Ceiling Cassette-4 Way Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDTC Ceiling Cassette-4 Way Compact Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDTW Ceiling Cassette-2 Way Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDTS Ceiling Cassette-1 Way Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDU Duct Connected-High Static Pressure Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDUM Duct Connected-Low/Middle Static Pressure Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for different models and octave bands.

FDUT Duct Connected (thin)-Low Static Pressure Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for FDUT models at different airflow rates.

FDK Wall Mounted Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for FDK models at P-Hi and Heating modes.

FDE Ceiling Suspended Type Noise Level

Presents noise level data (Sound Pressure Level) in dB(A) for FDE models at different speed settings.

Capacity Tables

FDT Ceiling Cassette-4 Way Type Capacity Tables

Provides cooling and heating capacity data (TC, SHC) for FDT models across various indoor and outdoor air temperatures.

Option Parts

Motion Sensor Kit Installation and Settings

Details the installation of the motion sensor kit, including mounting precautions, wiring, and setting procedures via remote controls.

Motion Sensor Setup

Eco Touch Remote Control Setting for Motion Sensor

Guides on setting the infrared sensor (motion sensor) control via the eco touch remote control screen.

Wireless Remote Control Setting for Motion Sensor

Details how to set indoor functions and the infrared sensor/motion sensor control via wireless remote.

Safety Precautions

Motion Sensor Power Control Settings

Explains how to set power control based on activity level detected by the motion sensor.

Motion Sensor Auto-Off Settings

Details the auto-off function of the motion sensor, including operation wait and complete stop states.