EasyManua.ls Logo

Mitsubishi Heavy Industries FDK22KXZE1 User Manual

Mitsubishi Heavy Industries FDK22KXZE1
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL MANUAL
Manual No.'19 • KX-T-310D
Note:
(INDOOR UNIT)
VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS
Duct connected-High
static pressure type
compact type
Ceiling cassette-4 way type
FDT28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
112KXZE1
140KXZE1
160KXZE1
Wall mounted type
FDK15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
FDE36KXZE1
45KXZE1
56KXZE1
71KXZE1
112KXZE1
140KXZE1
Ceiling cassette-4 way
FDTC15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
Ceiling cassette-2 way type
FDTW28KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
Ceiling cassette-1 way type
FDTS45KXE6F
71KXE6F
Ceiling suspended type
FDU650FKXZE1
1100FKXZE1
1800FKXZE1
2400FKXZE1
Outdoor air processing unit
FDU45KXE6F
Duct connected (thin)-Low
static pressure type
FDUT71KXE6F-E
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
224KXZE1
280KXZE1
Duct connected-Low/Middle
static pressure type
FDUM22KXE6F
28KXE6F
36KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
(1) This document describes the indoor units with service code /F (with motion sensor system
function).
DRAFT

Questions and Answers:

Mitsubishi Heavy Industries FDK22KXZE1 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDK22KXZE1
Cooling Capacity2.2 kW
Heating Capacity2.5 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Indoor Unit Dimensions (W x H x D)790 x 290 x 230 mm
Outdoor Unit Dimensions (W x H x D)780 x 540 x 290 mm
TypeSplit System
Noise Level (Outdoor Unit)50 dB

Summary

Product Specifications

Ceiling Cassette 4-Way Type (FDT) Specifications

Detailed specifications for FDT series ceiling cassette 4-way indoor units, including capacities, power, and electrical data.

Ceiling Cassette 4-Way Compact Type (FDTC) Specifications

Detailed specifications for FDTC series ceiling cassette 4-way compact indoor units, covering capacities and electrical data.

Ceiling Cassette 2-Way Type (FDTW) Specifications

Specifications for FDTW series ceiling cassette 2-way indoor units, including capacities, power, and electrical data.

Ceiling Cassette 1-Way Type (FDTS) Specifications

Specifications for FDTS series ceiling cassette 1-way indoor units, detailing capacities, power requirements, and electrical data.

Duct Connected High Static Pressure Type (FDU) Specifications

Specifications for FDU series duct-connected indoor units with high static pressure capabilities.

Duct Connected Low/Middle Static Pressure Type (FDUM) Specifications

Specifications for FDUM series duct-connected indoor units with low/middle static pressure capabilities.

Duct Connected Thin Low Static Pressure Type (FDUT) Specifications

Specifications for FDUT series thin duct-connected indoor units with low static pressure.

Wall Mounted Type (FDK) Specifications

Specifications for FDK series wall-mounted indoor units, including capacity, power, and electrical details.

Ceiling Suspended Type (FDE) Specifications

Specifications for FDE series ceiling-suspended indoor units, covering capacities, power, and electrical data.

Outdoor Air Processing Unit (FDU-F) Specifications

Specifications for FDU-F series outdoor air processing units, detailing capacities and electrical information.

Indoor Unit Exterior Dimensions

Indoor Unit Installation Dimensions

Detailed exterior dimensions, installation space, and mounting points for indoor units with diagrams.

Electrical Wiring Diagrams

FDT Series Ceiling Cassette 4-Way Type Wiring

Electrical wiring diagram and component identification for FDT series indoor units.

Noise Level Specifications

FDT Series Ceiling Cassette 4-Way Noise Levels

Sound pressure and power level data for FDT series ceiling cassette 4-way indoor units across various frequencies.

FDTC Series Ceiling Cassette 4-Way Compact Noise Levels

Noise level specifications for FDTC series compact ceiling cassette units, presented in octave band frequency charts.

FDTW Series Ceiling Cassette 2-Way Noise Levels

Noise level data for FDTW series ceiling cassette 2-way indoor units, detailed by speed and frequency.

FDTS Series Ceiling Cassette 1-Way Noise Levels

Noise level specifications for FDTS series ceiling cassette 1-way indoor units, including sound pressure and power levels.

FDU Series Duct Connected High Static Pressure Noise Levels

Noise level data for FDU series duct-connected units with high static pressure, across different speed settings.

FDUM Series Duct Connected Low/Middle Static Pressure Noise Levels

Noise level specifications for FDUM series duct-connected units with low/middle static pressure.

FDUT Series Duct Connected Thin Low Static Pressure Noise Levels

Noise level data for FDUT series thin duct-connected indoor units with low static pressure.

FDK Series Wall Mounted Type Noise Levels

Noise level specifications for FDK series wall-mounted indoor units, including cooling and heating modes.

FDE Series Ceiling Suspended Type Noise Levels

Noise level data for FDE series ceiling-suspended indoor units, measured according to JIS B 8616.

FDU-F Series Outdoor Air Processing Unit Noise Levels

Noise level specifications for FDU-F series outdoor air processing units, presented in decibels.

Indoor Unit Capacity Tables

FDT Series Ceiling Cassette 4-Way Capacity Tables

Cooling and heating capacity tables for FDT series indoor units, specified by air flow and various temperature conditions.

FDTC Series Ceiling Cassette 4-Way Compact Capacity Tables

Capacity tables for FDTC series compact ceiling cassette units, detailing cooling and heating performance.

FDTW Series Ceiling Cassette 2-Way Capacity Tables

Cooling and heating capacity data for FDTW series ceiling cassette 2-way indoor units.

FDTS Series Ceiling Cassette 1-Way Capacity Tables

Capacity tables for FDTS series ceiling cassette 1-way indoor units, showing performance across different temperature conditions.

FDU Series Duct Connected High Static Pressure Capacity Tables

Cooling and heating capacity data for FDU series duct-connected indoor units with high static pressure.

FDUM Series Duct Connected Low/Middle Static Pressure Capacity Tables

Capacity tables for FDUM series duct-connected indoor units with low/middle static pressure.

FDUT Series Duct Connected Thin Low Static Pressure Capacity Tables

Capacity data for FDUT series thin duct-connected indoor units with low static pressure.

FDK Series Wall Mounted Type Capacity Tables

Cooling and heating capacity tables for FDK series wall-mounted indoor units.

FDE Series Ceiling Suspended Type Capacity Tables

Capacity data for FDE series ceiling-suspended indoor units, presented in tables for various conditions.

FDU-F Series Outdoor Air Processing Unit Capacity Tables

Capacity tables for FDU-F series outdoor air processing units, including cooling and heating performance.

Option Parts and Accessories

Motion Sensor Kit Installation and Settings

Instructions for installing and setting up the motion sensor kit (LB-T-5W-E) for FDT series units.

Related product manuals