STANDARD INVERTER PACKAGED AIR-CONDITIONERS
V Multi System
(Split system, Air to air heat pump type)
Manual No. '10 PAC-DB-142
DATA BOOK
CEILING CASSETTE-4 WAY COMPACT TYPE
Single type
FDTC40ZIXVD
50ZIXVD
60ZIXVD
Triple type
FDTC140VNTVD
140VSTVD
Single type
FDT40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDT140VNTVD
140VSTVD
200VSTVD
Single type
FDEN40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDEN140VNTVD
140VSTVD
200VSTVD
Twin type
FDEN71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
CEILING CASSETTE-4 WAY TYPE
DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE
CEILING SUSPENDED TYPE
Single type
FDUM50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDUM140VNTVD
140VSTVD
200VSTVD
DUCT CONNECTED-HIGH STATIC PRESSURE TYPE
Single type
FDU71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
Twin type
FDUM100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Twin type
FDT71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Double Twin type
FDT200VSDVD
250VSDVD
Twin type
FDTC71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
Double Twin type
FDTC200VSDVD
FDTC250VSDVD
FDU140VNVD
140VSVD
200VSVD
250VSVD
(OUTDOOR UNIT)
FDC71VN
100VN
100VS
125VN
125VS
FDC140VN
140VS
200VS
250VS
(INDOOR UNIT)
FDT40VD
50VD
60VD
71VD
100VD
125VD
FDEN40VD
50VD
60VD
71VD
100VD
125VD
Ragarding the Service Manual please see the Manual No.’10 • PAC-SM-143.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDT100VD and is the answer not in the manual?

Mitsubishi Heavy Industries FDT100VD Specifications

General IconGeneral
RefrigerantR410A
Indoor Unit Dimensions (H x W x D)290 x 840 x 840 mm
Outdoor Unit Dimensions (H x W x D)845 x 970 x 370 (+97) mm
Weight (Indoor Unit)25 kg
Weight (Outdoor Unit)64 kg
Energy Efficiency Ratio (EER)3.21
Operating Temperature (Cooling)-15 to +46 °C
Operating Temperature (Heating)-15°C to 24°C

Summary

STANDARD INVERTER PACKAGED AIR-CONDITIONERS

SPECIFICATIONS

Detailed technical specifications for various air conditioning unit types, including FDTC, FDT, FDEN, FDUM, and FDU models.

EXTERIOR DIMENSIONS

Dimensional drawings and specifications for indoor and outdoor units, crucial for installation planning.

ELECTRICAL WIRING

Wiring diagrams and guidelines for connecting indoor and outdoor units, essential for safe installation.

NOISE LEVEL

Sound pressure level data for indoor and outdoor units across different frequency bands.

CHARACTERISTICS OF FAN

Fan performance curves showing static pressure vs. airflow for different models.

TEMPERATURE AND VELOCITY DISTRIBUTION

Diagrams illustrating airflow and temperature distribution patterns for indoor units.

PIPING SYSTEM

Refrigerant piping diagrams for different unit configurations, showing component connections.

RANGE OF USAGE & LIMITATIONS

Guidelines on operating conditions, installation limitations, and safety precautions for optimal system performance.

SELECTION CHART

Charts to assist in selecting models and correction factors for capacity based on conditions.

APPLICATION DATA

Data and instructions for applying the system, including installation details for indoor and outdoor units.

V MULTI SYSTEM

GENERAL INFORMATION

Provides general information including how to read model names and tables for V Multi systems.

SPECIFICATIONS

Detailed specifications for various indoor and outdoor units within the V Multi system.

EXTERIOR DIMENSIONS

Physical dimensions and installation space requirements for V Multi system units.

ELECTRICAL WIRING

Electrical wiring diagrams and connection instructions for V Multi systems.

NOISE LEVEL

Noise level data for V Multi system units across various models and conditions.

TEMPERATURE AND VELOCITY DISTRIBUTION

Airflow and temperature distribution characteristics for V Multi indoor units.

PIPING SYSTEM

Refrigerant piping diagrams for V Multi system configurations.

RANGE OF USAGE & LIMITATIONS

Operating conditions, limitations, and safety precautions for V Multi systems.

SELECTION CHART

Charts to assist in selecting V Multi system components and combinations.

APPLICATION DATA

Data and instructions related to applying the V Multi system, including installation details.

OPTION PARTS

WIRELESS KIT

Information and installation for wireless remote control kits for various series (FDTC, FDT, FDEN, FDUM/FDU).

SIMPLE WIRED REMOTE CONROLLER (RCH-E3)

Details on the simple wired remote controller, including its functions and operation.

FAN CONTROLLERT KIT (U-FCRA)

Information regarding the installation and use of the fan controller kit.

BASE HEATER KIT (CW-H-E)

Installation instructions for the base heater kit to prevent freezing in low temperatures.

Related product manuals