Manual No. '07·PAC-T-115
T E C H N I C A L M A N U A L
C o l l e c t i o n d a t a
PACKAGED AIR-CONDITIONER
MULTI-TYPE (V-MULTI)
PACKAGED AIR-CONDITIONER
(Split system, Air to air heat pump type)
CEILING RECESSED COMPACT TYPE
CEILING RECESSED TYPE
WALL MOUNTED TYPE
CEILING SUSPENDED TYPE
FDTCVA151HEN1R
201HEN1R
(OUTDOOR UNIT)
FDCVA302HENR
402HENAR
402HESAR
502HENAR
502HESAR
602HENAR
602HESAR
802HESAR
1002HESAR
FDTA151R
201R
251R
301R
401R
501R
(INDOOR UNIT)
FDTCA151R
201R
FDTCVA302HENP1R
402HENP2R
402HESP2R
FDTCVA602HENT2R
602HEST2R
FDTVA151HEN1R
201HEN1R
251HEN1R
302HEN1R
402HEN2R
402HES2R
502HEN2R
502HES2R
602HEN2R
602HES2R
FDTVA302HENP1R
402HENP2R
402HESP2R
502HENP2R
502HESP2R
602HENP2R
602HESP2R
802HESP2R
1002HESP2R
FDTVA602HENT2R
602HEST2R
802HEST2R
FDTVA802HESD2R
1002HESD2R
FDKNVA151HEN1R
201HEN1R
251HEN1R
FDKNVA302HENP1R
402HENP2R
402HESP2R
502HENP2R
502HESP2R
FDKNVA602HENT2R
602HEST2R
FDENVA151HEN1R
201HEN1R
251HEN1R
302HEN1R
402HEN2R
402HES2R
502HEN2R
502HES2R
602HEN2R
602HES2R
FDENVA302HENP1R
402HENP2R
402HESP2R
502HENP2R
502HESP2R
602HENP2R
602HESP2R
802HESP2R
1002HESP2R
FDENVA602HENT2R
602HEST2R
802HEST2R
SATELLITE DUCTED TYPE
FDUMVA201HEN2R
251HEN2R
302HEN2R
402HEN2R
402HES2R
502HEN2R
502HES2R
602HEN2R
602HES2R
FDUMVA402HENP2R
402HESP2R
502HENP2R
502HESP2R
602HENP2R
602HESP2R
802HESP2R
1002HESP2R
FDUMVA602HENT2R
602HEST2R
802HEST2R
FDEN
A
151R
201R
251R
301R
401R
501R
FDKNA151R
201R
251R
FDUMA202R
252R
302R
402R
502R
HIGH STATIC PRESSURE DUCT TYPE
FDUVA802HES2R
1002HES2R
updated 3,October,2008

Table of Contents

Questions and Answers:

Mitsubishi Heavy Industries FDTA501R Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDTA501R
CategoryAir Conditioner
LanguageEnglish

Summary

Packaged Air-Conditioner

General Information

Provides details on specific features and model naming conventions.

Specific Features

Highlights key features like R410A compliance, high COP, energy labeling, and microcomputer control.

How to Read Model Name

Explains the structure and meaning of model codes for different unit types.

Selection Data

Contains specifications, range of usage, exterior dimensions, and performance data for unit selection.

Specifications

Lists detailed technical specifications for various unit types including capacity, power source, and refrigerant.

Range of Usage & Limitations

Outlines operating temperature limits, installation site restrictions, and prohibited locations.

Exterior Dimensions

Provides dimensional drawings and measurements for indoor and outdoor units.

Piping System

Illustrates refrigerant piping diagrams for different model configurations and connections.

Noise Level

Presents noise level data in octave bands for indoor and outdoor units.

Electrical Data

Details wiring diagrams, parts, color codes, and switch settings for indoor and outdoor units.

Indoor Unit Electrical Wiring

Shows the wiring diagram for indoor units, including PCB layout and switch functions.

Outdoor Unit Electrical Wiring

Provides wiring diagrams for outdoor units, detailing PCB layouts, connections, and components.

Operation Control

Explains how the microcomputer controls system operation, including remote controller functions and diagnostic modes.

Wired Remote Controller

Details the layout, functions, and operation of the wired remote controller.

Wireless Remote Controller

Explains the indicators and buttons on the wireless remote controller and its operation.

Indoor Controller Operation

Describes room temperature control, automatic operation, and control part functions.

Outdoor Controller Operation

Explains compressor speed control, soft start, and outdoor fan control logic.

Application Data

Covers installation procedures for indoor and outdoor units, including mounting, piping, and wiring.

Indoor Unit Installation

Details selection of installation location and installation space for various indoor unit types.

Outdoor Unit Installation

Covers haulage, installation location, mounting, piping, and wiring for outdoor units.

Refrigerant Charge

Provides methods for calculating and performing refrigerant charging based on piping length and model.

Maintenance Data

Covers maintenance procedures like evacuation, troubleshooting, and diagnostics.

Evacuation

Explains the process of purging impurities and moisture using a vacuum pump.

Troubleshooting Refrigerant Circuit

Guides on diagnosing operating pressure and temperature differences to identify circuit issues.

Diagnosing Microcomputer Circuit

Details self-diagnosis functions and error codes for indoor and outdoor units.

Check Display on Wireless Models

Explains the meaning of LED indicators on wireless units for operation status and error codes.

Multi-Type (V-MULTI) Packaged Air-Conditioner

General Information

Provides an overview of specific features, model naming, and system combinations for multi-type units.

Specific Features

Highlights features like flexible indoor unit selection, R410A compliance, and advanced microcomputer control.

How to Read Model Name

Explains the model naming convention for multi-type V-MULTI systems.

Selection Data

Contains specifications, range of usage, dimensions, and operating characteristics for multi-type systems.

Indoor Unit Specifications

Lists detailed specifications for various indoor unit types (FDTC, FDT, FDEN, FDKN, FDUM).

Outdoor Unit Specifications

Provides detailed specifications for outdoor units used in multi-type systems.

Calculation of Total Operation Characteristics

Explains how to calculate system operation characteristics based on indoor and outdoor unit combinations.

Range of Usage & Limitations

Outlines operating temperature limits, installation site restrictions, and prohibited locations.

Exterior Dimensions

Provides dimensional drawings and measurements for indoor and outdoor units.

Piping System

Illustrates refrigerant piping diagrams for different model configurations and connections.

Noise Level

Presents noise level data in octave bands for indoor and outdoor units.

Electrical Data

Details wiring diagrams, parts, color codes, and switch settings for indoor and outdoor units.

Operation Control

Explains how the microcomputer controls system operation.

Application Data

Covers installation procedures for indoor and outdoor units.

Maintenance Data

Covers maintenance procedures like evacuation, troubleshooting, and diagnostics.

Wireless Kit (Optional Parts)

Wireless Kit Model and Paint Color

Specifies the model number and paint color for the wireless kit.

Accessories for Wireless Kit

Lists the components included with the wireless kit, such as receiver and remote controller holder.

Receiver Installation and Function

Describes the physical layout of the receiver and its operational indicators.

Related product manuals