'14 • SRK-T-155
(b) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(10)
Timer operation
(a) Comfortable timer setting (ON timer)
(c) OFF timer operation
The Off timer can be set at a specic time (in 10-minute units) within a 24-hour period.
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto
mode operation is selected, the comfortable timer starts and determines the starting time of next operation based on the initial
value of 15 minutes and the relationship between the indoor temperature at the setting time (temperature of room tempera-
ture sensor) and the setting temperature.
(13)
Installation location setting
When the indoor unit is installed at the end of a room, control the air ow direction so that it is not toward the side walls. If you set
the wireless remote control installation position, keep it so that the air ow is within the range shown in the following gure.
(a) Setting
(i)
If the air conditioning unit is running, press the ON/OFF button to stop.
The installation location setting cannot be made while the unit is running.
(ii)
Press the AIR FLOW
(UP/DOWN) button and the
AIRFLOW
(LEFT/RIGHT) button together for 5 seconds
or more.
The installation location display illuminates.
(iii)
Setting the air-conditioning installation location.
Press the AIR FLOW
(LEFT/RIGHT) button and adjust to the desired
location.
Each time the AIR FLOW
(LEFT/RIGHT) button is pressed, the
indicator is switched in the order of:
(Center Installation) (Right End Installation) (Left End Installation)
(11)
Silent mode
As “Silent mode start” signal is received from the wireless remote control, it operates by dropping the outdoor fan tap and the
compressor command speed.
(12)
Night setback
As “Night setback” signal is received from the wireless remote control, the heating operation starts with the setting temperature
at 10
.
Outdoor fan tap
(Upper limit)
Compressor command
speed (Upper limit)
Cooling Heating Cooling Heating Cooling Heating
Cooling Heating
SRK20ZMXA-S SRK25ZMXA-S SRK35ZMXA-S SRK50ZMXA-S
4th speed
30 rps
4th speed
40 rps
4th speed
34 rps
4th speed
46 rps
5th speed
50 rps
4th speed
60 rps
5th speed
52 rps
5th speed
52 rps
Cooling Heating
SRK60ZMXA-S
5th speed
52 rps
5th speed
52 rps
( i ),( iv )
( ii )
(iii)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRK20ZMXA-S and is the answer not in the manual?

Mitsubishi Heavy Industries SRK20ZMXA-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRK20ZMXA-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals