EasyManua.ls Logo

Mitsubishi Heavy Industries SRK63HE-S1 User Manual

Mitsubishi Heavy Industries SRK63HE-S1
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
-
3
-
INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER
( Split system, air to air heat pump type )
SRK20ZD-S1, SRK25ZD-S1, SRK35ZD-S1, SRK50ZD-S1
SRK63ZE-S1, SRK71ZE-S1
WALL MOUNTED TYPE ROOM AIR-CONDITIONER
( Split system, air to air heat pump type )
SRK20HD-S1, SRK28HD-S1, SRK40HD-S1
SRK20HC-S2, SRK28HC-S2, SRK40HC-S2
SRK50HE-S1, SRK56HE-S1
SRK63HE-S1, SRK71HE-S1
WALL MOUNTED TYPE ROOM AIR-CONDITIONER
( Split system, air cooled cooling only type )
SRK20CD-S1, SRK28CD-S1, SRK40CD-S1
SRK20CC-S1, SRK28CC-S1, SRK40CC-S1
SRK50CE-S1, SRK56CE-S1
SRK63CE-S1, SRK71CE-S1
Manual No. ’06
.
SRK-T
.
050
updated September 29, 2009

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRK63HE-S1 and is the answer not in the manual?

Mitsubishi Heavy Industries SRK63HE-S1 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRK63HE-S1
CategoryAir Conditioner
LanguageEnglish

Summary

1.1.1 GENERAL INFORMATION

(1) Specific features

Details the general characteristics and technologies of the SRK series air conditioners.

(2) How to read the model name

Explains the nomenclature used in the model numbers for identification.

1.1.2 SELECTION DATA

(1) Specifications

Provides detailed technical specifications for the SRK20ZD-S1 and SRC20ZD-S1 models.

(2) Range of usage & limitations

Defines the operational limits and environmental conditions for specific models.

(3) Exterior dimensions

Provides physical dimensions for the indoor unit of selected models.

(3) Exterior dimensions (a) Indoor unit

Provides physical dimensions for the indoor unit of selected SRK20ZD-S1, 25ZD-S1, 35ZD-S1, 50ZD-S1 models.

(3) Exterior dimensions (b) Outdoor unit

Provides physical dimensions for the outdoor unit of selected SRC20ZD-S1, 25ZD-S1, 35ZD-S1 models.

1.1.3 ELECTRICAL DATA

(1) Electrical wiring

Presents the electrical wiring diagram for the SRK20ZD-S1, 25ZD-S1, 35ZD-S1 models.

1.1.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

(1) Operation control function by remote control switch

Explains the functions and operation of the remote control buttons and indicators.

(3) Power blackout auto restart function

Describes the function that resumes operation after a power interruption.

(4) Flap control

Details the automatic control of the flap and louver functions via the remote.

(5) Comfortable timer setting

Explains how the timer adjusts operation start time based on temperature differences.

(6) Outline of heating operation

(a) Operation of major functional components in heating mode

Describes the function of key components during heating operations.

(7) Outline of cooling operation

(a) Operation of major functional components in Cooling mode

Describes the function of key components during cooling operations.

(8) Outline of dehumidifying operation

(b) Outline of control

Explains the control logic for cooling and heating oriented dehumidifying operations.

(11) Protective control function

(a) Frost prevention for indoor heat exchanger (During cooling or dehumidifying)

Details the function and conditions for preventing frost on the indoor heat exchanger.

1.1.5 APPLICATION DATA

SAFETY PRECAUTIONS

Lists critical safety precautions for installation and use.

(1) Selection of location for installation

Provides guidelines for choosing suitable locations for indoor and outdoor unit installation.

(2) Installation of indoor unit

Details the procedure for installing the indoor unit, including board mounting and drilling.

(c) Preparation of indoor unit

Explains how to mount connecting wires and form the piping.

(d) Installation on indoor unit

Guides the user on how to install the indoor unit onto the mounting plate.

(4) Refrigerant piping

Covers the preparation and connection of refrigerant piping for installation.

1.1.6 MAINTENANCE DATA

(1) Troubleshooting procedures for electrical equipment

Provides steps for diagnosing and resolving electrical equipment issues.

(e) Self-diagnosis table

Lists error codes displayed by the unit and their corresponding causes and symptoms.

(d) Troubleshooting procedure (If the air conditioner runs)

Outlines the steps for troubleshooting when the air conditioner is running but malfunctioning.

1.1.7 REFRIGERANT PIPING INSTALLATION/SERVICING MANUAL FOR AIR CONDITIONERS USING R410A

(1) Outline

Provides an overview of the R410A refrigerant and its adoption in air conditioners.

(a) Refrigerant R410A

Discusses the adoption of R410A, its properties, and environmental considerations.

(2) Refrigerant piping installation

Covers the selection and installation of copper pipes and joints for refrigerant piping.

2.1.1 GENERAL INFORMATION

(1) Specific features

Details the general characteristics and technologies of the SRK series wall-mounted air conditioners.

(2) How to read the model name

Explains the nomenclature used in the model numbers for identification.

2.1.2 SELECTION DATA

(1) Specifications

Provides detailed technical specifications for the SRK20HD-S1 and SRC20HD-S1 models.

(2) Range of usage & limitations

Defines the operational limits and environmental conditions for specific models.

(3) Exterior dimensions

Provides physical dimensions for the indoor unit of selected models.

2.1.3 ELECTRICAL DATA

(1) Electrical wiring

Presents the electrical wiring diagram for the SRK63ZE-S1, 71ZE-S1 models.

2.1.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

(1) Operation control function by remote control switch

Explains the functions and operation of the remote control buttons and indicators.

(3) Power blackout auto restart function

Describes the function that resumes operation after a power interruption.

(6) Outline of heating operation (Heat pump type only)

(a) Operation of major functional components

Describes the function of key components during heating operations.

(7) Outline of cooling operation

(a) Operation of major functional components

Describes the function of key components during cooling operations.

(8) Outline of dehumidifying operation

(b) Outline of control

Explains the control logic for cooling and heating oriented dehumidifying operations.

(10) Outline of automatic operation

(a) Determination of operation mode

Explains how the unit determines the operation mode based on temperature.

(11) Outline of fan operation (Cooling only type only)

(a) Operation of major functional components

Describes the function of key components during cooling-only fan operations.

(12) Protective control function

(a) Frost prevention for indoor heat exchanger (During cooling or dehumidifying)

Details the function and conditions for preventing frost on the indoor heat exchanger.

2.1.5 APPLICATION DATA

SAFETY PRECAUTIONS

Lists critical safety precautions for installation and use.

(1) Selection of location for installation

Provides guidelines for choosing suitable locations for indoor and outdoor unit installation.

(2) Installation of indoor unit

Details the procedure for installing the indoor unit, including board mounting and drilling.

(c) Preparation of indoor unit

Explains how to mount connecting wires and form the piping.

(d) Installation of outdoor unit

Guides the user on how to install the outdoor unit.

(4) Refrigerant piping

Covers the preparation and connection of refrigerant piping for installation.

2.1.6 MAINTENANCE DATA

(1) Troubleshooting procedures for electrical equipment

Provides steps for diagnosing and resolving electrical equipment issues.

(e) Self-diagnosis table

Lists error codes displayed by the unit and their corresponding causes and symptoms.

(d) Troubleshooting procedure (If the air conditioner runs)

Outlines the steps for troubleshooting when the air conditioner is running but malfunctioning.

2.1.7 REFRIGERANT PIPING INSTALLATION/SERVICING MANUAL FOR AIR CONDITIONERS USING R410A

(1) Outline

Provides an overview of the R410A refrigerant and its adoption in air conditioners.

(a) Refrigerant R410A

Discusses the adoption of R410A, its properties, and environmental considerations.

(2) Refrigerant piping installation

Covers the selection and installation of copper pipes and joints for refrigerant piping.

3.1.1 GENERAL INFORMATION

(1) Specific features

Details the general characteristics and technologies of the SRK series cooling-only air conditioners.

(2) How to read the model name

Explains the nomenclature used in the model numbers for identification.

3.1.2 SELECTION DATA

(1) Specifications

Provides detailed technical specifications for the SRK50CE-S1 and SRC50CE-S1 models.

(2) Range of usage & limitations

Defines the operational limits and environmental conditions for specific models.

(3) Exterior dimensions

Provides physical dimensions for the indoor unit of selected models.

3.1.3 ELECTRICAL DATA

(1) Electrical wiring

Presents the electrical wiring diagram for the SRK20CD-S1, 28CD-S1, 40CD-S1, 20CC-S1, 28CC-S1, 40CC-S1 models.

3.1.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

3.1.5 APPLICATION DATA

3.1.6 MAINTENANCE DATA

3.1.7 REFRIGERANT PIPING INSTALLATION/SERVICING MANUAL FOR AIR CONDITIONERS USING R410A