4 Mildew Guard mode
(a) Alternately activates/deactivates compressor or blower according to current humidity/time. (Fan rank is as shown in 2)
(b) Operates dehumidifier when Mildew guard mode is activated or every 24 hours after activation.
(c) Dehumidifier is deactivated when the following parameters are breached. (Compressor and blower stop)
•2 hours of below 40% elapses and below 35% is detected.
•4 hours of below 50% elapses and below 45% is detected.
* However, if the humidity rises above the given levels for more than 3 minutes, the accumulated time returns to zero.
(d) If the humidity rises to 75% after deactivation, the dehumidifier automatically operates until the humidity is brought down to 65%.
(e) If 24 hours elapse from the time the unit was turned on, all accumulated time counts for all humidity levels are reset.
2HR 2HR
4HR4HR
45%
Elapsed time
35%
Elapsed time
Humidity level
Compressor
Blower
Mildew
Guard
ON
Below 45%
time count
start
Below 35%
time count
start
Below 35%
time count
stop
Dehumidifier
activated
Below 35%
time count
start
Dehumidifier
deactivated
Dehumidifier
deactivated
Dehumidifier
deactivated
Accumulated
time counts
reset
65%
45%
40%
35%
24HR
75%
ON
OFF
Below
45%
Below
35%
3 minutes
above 40%
elapse
Limit
75%
Limit
recovered 65%
14
<Operation Control>
1 Humidity set operation
(a) Compressor and blower fan operation will switch by current humidity and set temperature.
2 Specifications shared at all operation modes
(a) Dehumidifying will not start for about 2 seconds when turning the operation power on with the swing stopped. (However, humidifying
will begin immediately when pressing the swing louvre switch within 2 seconds of turning the power on.)
(b) The compressor and blower fan will operate for about 7 minutes after turning on the operation switch or activating the compressor,
regardless of humidity or temperature levels.
3 Low, Low Temp, Mildew Guard, Air Purifier, Laundry
Compressor
ON
Rank 1
Rank 1
Rank 2
Rank 2
Rank 5
Rank 5
Stopped
Stopped
Stopped
27°C34°C
29°C
36°C
ON
OFF
Current humidity
– Set humidity
Decline in
current
humidity
+3%
–1%
+5%
+1%
Rise in current
humidity
Blower fan rank
Mildew Guard E16SX only
Low
Air Purifier E16S only
Low Temp
Laundry E16S only
Laundry E16SX only
ON ON
ON
ON
––
––
ON
ON
Compressor
OFF
ON
Rank 1 Rank 1 Rank 1 Rank 1
Rank 1 Rank 1
Rank 1Rank 1
Rank 6
Rank 2 Rank 2
Rank 2 Rank 2 Rank 5
Rank 5
Rank 5
E16S
E16S
E16SX E16SX E16SX E16SX E16SX
E16S E16S E16S
Rank 5
Rank 5
Rank 5
Rank 5
Rank 2
Rank 2 Rank 2
Rank 2
Rank 2
Rank 3 Rank 4 Rank 4
Rank 4 Rank 4
Rank 3
Rank 6
14°C
27
°C
34
°C
16°C 29°C
Blower fan rank
36°C
E16SX
E16SX
E16SX
E16S E16SX