Do you have a question about the Mitsubishi MSZ-HJ25VA and is the answer not in the manual?
Indoor unit type | Wall-mountable |
---|---|
Indoor unit width | - mm |
Indoor unit weight | 9000 g |
Indoor units quantity | 1 |
Cooling airflow (indoor unit) | 571 m³/h |
Heating airflow (indoor unit) | 598 m³/h |
Indoor unit dimensions (WxDxH) | 799 x 232 x 290 mm |
Indoor unit noise level (high speed) | 57 dB |
Type | Air conditioner indoor unit |
Ionizer | No |
Multi-split | - |
Product color | White |
Remotely operated | Yes |
Cooling capacity (max) | - BTU/h |
Air conditioner functions | Cooling, Heating |
Cooling capacity in watts (max) | 3700 W |
Heating capacity in watts (max) | 4200 W |
Seasonal efficiency rating (cooling) (SEER) | 5.1 |
Heating capacity in watts (nominal) (Warmer heating season) | - W |
Seasonal efficiency rating (heating) (SCOP) (Average heating season) | 3.8 |
Airflow (low speed) | 227 m³/h |
Airflow (high speed) | 438 m³/h |
Airflow (medium speed) | 328 m³/h |
Noise level (low speed) | 22 dB |
Noise level (high speed) | 37 dB |
Noise level (medium speed) | 30 dB |
Design load (cooling) | 2.5 kW |
Energy efficiency class (cooling) | A |
Power consumption (cooling) (max) | 730 W |
Power consumption (heating) (max) | 870 W |
Annual energy consumption (cooling) | 171 kWh |
Hourly energy consumption (cooling) | - kWh |
Design load (heating) (Warmer heating season) | - kW |
Design load (heating) (Average heating season) | 1.9 kW |
Annual energy consumption (heating) (Average heating season) | 698 kWh |
Outdoor unit noise level | 63 dB |
Shortens compressor start time for servicing via P.C. board point.
Modifies remote controller P.C. boards for multi-unit operation.
Unit restarts automatically in same mode after power interruption.
Details the operation of the air conditioner in cooling mode.
Details the operation of the air conditioner in dry mode.
Details the operation of the air conditioner in heating mode.
Explains the automatic horizontal vane control and modes.
Instructions for setting ON/OFF timers for the air conditioner.
Procedures for emergency and test run operations.
Protects the compressor from overload with a 3-minute delay.
Important safety precautions and checks before performing troubleshooting.
Explains how to recall and check stored failure information.
Step-by-step instructions and flowcharts for diagnosing issues.
A table mapping abnormal points to symptoms, conditions, and remedies.
Criteria and methods for checking main components like thermistors and motors.
Detailed flowcharts for troubleshooting specific issues like fan motor errors.
Provides diagrams of test points and voltage references on P.C. boards.
Step-by-step guide for disassembling smaller capacity indoor units.
Step-by-step guide for disassembling larger capacity indoor units.