EasyManuals Logo

Mitsubishi QD75M2 User Manual

Mitsubishi QD75M2
882 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #547 background imageLoading...
Page #547 background image
12 - 18
MELSEC-Q
12 CONTROL SUB FUNCTIONS
AL has a significant number to first decimal place, round down numbers to
two decimal places.
Reduce a fraction in the above result.
AP AP 2605056 2605056 (AP)
S
=
AL
×
AM
=
2968805.0
=
2968805.0 (AL)
×
1(AM)
Thus, AP, AL and AM
to be set are as follows.
AP
= 2605056 …….
Pr.2
AL
= 2968805.0 …..
Pr.3
AM
= 1 …………..…
Pr.4
This setting will produce an error for the true machine value, but it cannot
be helped. This error is as follows.
29688050/2605056
9450000
×
2605056
- 1
×
100 = -1.94
×
10
–6
[%]
It is equivalent to an about 19.4[
µ
m] error in continuous 1km feed.