Questions and Answers

  • N
    Nicholas TaylorAug 3, 2025
    What to do if a Mitsubishi QY42P Controller input signal does not turn off?
    • P
      pamelacrawfordAug 3, 2025
      If a Mitsubishi Controller input signal does not turn off, it could be due to several reasons: * Leakage current of the input switch. To resolve this, connect an appropriate resistor so that the voltage across the terminals of the input module will be less than the off voltage. Using a 0.1 to 0.47 F + 47 to 120? (1/2W) for the CR constant is recommended. * Drive by a limit switch with neon lamp. The suggested solution is the same as above, or you can create another independent display circuit. * Leakage current due to line capacity of wiring cable. The suggested solution is the same as the first point. However, leakage current is not generated when the power supply is located in the input equipment side.

Summary

SAFETY PRECAUTIONS

Design Precautions

Details safety considerations for system design and external circuits.

Installation Precautions

Covers safe installation procedures for programmable controllers and modules.

Wiring Precautions

Provides guidelines for safe and correct electrical wiring of modules.

Startup and Maintenance Precautions

Covers essential precautions for starting up and maintaining the system.

GENERAL SPECIFICATIONS AND PRECAUTIONS FOR USE

Precautions for Use

Details safety precautions related to the usage of input and output modules.

Input module Precautions

Covers precautions for using input modules, including response time and noise.

Output module Precautions

Explains precautions for using output modules, including load connection and fuses.

I;O combined module

Describes I/O numbers and configuration for I/O combined modules.

I;O module with protection function

Explains overload and overheat protection functions in specific I/O modules.

Installation and wiring

Covers proper installation and wiring procedures for modules.

Various Settings for I;O Module

Details various configuration settings for I/O modules using GX Developer.

INPUT MODULE SPECIFICATIONS

QX10 AC Input Module

Provides specifications for the QX10 AC input module, including electrical characteristics and connections.

QX10-TS AC Input Module

Details specifications for the QX10-TS AC input module, highlighting spring clamp terminals.

QX28 AC Input Module

Lists specifications for the QX28 AC input module, including voltage and current ratings.

QX40 DC Input Module (Positive Common Type)

Provides specifications for the QX40 DC input module with positive common type.

QX40-S1 DC Input Module (Positive Common Type)

Details specifications for the QX40-S1 DC input module, focusing on response time settings.

QX40-TS DC Input Module (Positive Common Type)

Lists specifications for the QX40-TS DC input module with spring clamp terminals.

QX40 H DC High-Speed Input Module (Positive Common Type)

Explains specifications for the QX40H high-speed input module, including switch settings for function.

QX70 H DC High-speed Input Module (Positive Common Type)

Details specifications for the QX70H high-speed input module, including noise immunity.

QX80 H DC High-speed Input Module (Negative Common Type)

Explains specifications for the QX80H high-speed input module, including function selector switch settings.

OUTPUT MODULE SPECIFICATIONS

QY41 H Transistor High-speed Output Module (Sink Type)

Provides specifications for the QY41H high-speed transistor output module (sink type).

I;O COMBINED MODULE

INTERRUPT MODULE

CONNECTORS

SPECIFICATIONS OF CONNECTOR;TERMINAL BLOCK CONVERTER MODULES

SPRING CLAMP TERMINAL BLOCK

I;O MODULE TROUBLESHOOTING

Input Circuit Troubleshooting

Explains common problems with input circuits and provides corrective actions.

Output Circuit Troubleshooting

Describes common problems with output circuits and their corresponding corrective actions.

Mitsubishi QY42P Specifications

General IconGeneral
ModelQY42P
Product SeriesMELSEC-Q
TypeTransistor Output Module
Number of Output Points32 points
Rated Load Voltage12/24 V DC
Insulation MethodPhotocoupler insulation
Response Time0.1 ms
Rated Load Current0.1 A/point
SeriesMELSEC-Q Series
Mounting TypeDIN Rail
Output TypeSink type