Note (1)  Even in cases  where only intermittent stop data are  generated,  the air conditioning system is normal. However, if the same protective operation recurs 
repeatedly (3 or more times), it will lead to customer complaints. Judge the conditions in comparison with the contents of the complaints.
Conrm the contents of the customer complaint.
Check the self-diagnosis display.
Eliminate the cause of the trouble and perform an 
operation check.
Replace the faulty component, then perform an 
operation check.
Identify the faulty component by using the check 
procedure corresponding to the content of the trouble.
The cause of the trouble can 
be specically identied.
See below.
(5)  Self-diagnosis table
When this air-conditioner performs an emergency stop, the reason why the emergency stop occurred is displayed by the ashing of 
display lights. If the air-conditioner is operated using the remote control 3 minutes or more after the emergency stop, the trouble 
display stops and the air-conditioner resumes operation. 
(1)
 
Notes  (1) The air-conditioner cannot be restarted using the remote control for 3 minutes after operation stops. 
When a heat exchanger sensor wire disconnection is detected while operation is 
stopped. (If a temperature of –20ºC or lower is detected for 15 seconds, it is 
judged that the wire is disconnected.) 
(Not displayed during operation.)
When a room temperature sensor wire disconnection is detected while operation 
is stopped. (If a temperature of –20ºC or lower is detected for 15 seconds, it is 
judged that the wire is disconnected.) 
(Not displayed during operation.)
• Broken heat exchanger sensor 
wire, poor connector 
connection
• Indoor PCB is faulty
• Broken room temperature 
sensor wire, poor connector 
connection
• Indoor PCB is faulty
When conditions for turning the indoor unit’s fan motor on exist during air- 
conditioner operation, an indoor unit fan motor speed of 300 min
-1
 or lower is 
measured for 30 seconds or longer. (The air-conditioner stops.)
• Defective fan motor, poor 
connector connection
ON
1-time
flash
ON
2-time
flash
ON
6-time
flash
When there is an emergency stop caused by trouble in the outdoor unit, or the 
input current value is found to be lower than the set value.
 (The air-conditioner stops.)
• Broken compressor wire
• Compressor blockage
• 
52
C
 relay in indoor PCB is faulty
• Improper wire connection 
between indoor and outdoor
2-time
flash
ON
Indoor unit display panel
Cause Display (flashing) condition
RUN
light
TIMER
light
Heat exchanger 
sensor error
Room
temperature
sensor error
Indoor fan 
motor error
Trouble of 
outdoor unit
Description
of trouble