 34 
-
'14•SRK-T-164
(b)
  The unit checks the temperature every 30 minutes after the start of operation and, if the result of check is not same as 
the previous operation mode, changes the operation mode.
(c)
  When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is 
selected during cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(d)
  Setting temperature can be adjusted within the following range. There is the relationship as shown below between the 
signals of the wireless remote control and the setting temperature.
           
 Signals of wireless remote control (Display)
     
–6  –5  –4  –3  –2  –1 
±
0  +1  +2  +3  +4  +5  +6
 
Setting
 
Cooling
  18  19  20  21  22  23  24  25  26  27  28  29  30
 
temperature
 
Dehumidifying
  18  19  20  21  22  23  24  25  26  27  28  29  30
(9)  Outline of cooling operation
(a)   Operation of major functional components in Cooling mode
(b)   Fan speed switching
(10)  Outline of automatic operation
(a)  Determination of operation mode
  The unit checks the indoor air temperature and the outdoor air temperature, determines the operation mode, and then 
begins in the automatic operation.
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
Room temperature
<
25.5
℃
25.5
℃≦
Room temperature
Operation mode Dehumidifying Cooling
21 Series
26 Series