Thefixtureisforindooruseonlyingeneralconditions.
Cannotbeusedfollowingconditions(Causesoffalling,electrocutionandfire)
●Ambienttemperatureunder0℃andover35℃
●Highhumidity
●Outside
●Onthefloor
●Insulatedinsideofceiling
●Vibratedorshockedareas
●Areasgetdirectsunlight
●Inclined,unevensurface
Ceilingwhichcanʼtholdthefixtureweight
●Onthewall
Placesaffectedbywindorair-conditionermachine
●Nearfire
Dustyareas,corrosivegasoutbreaksareas
Before
installation
Forelectric
wiring
Atlighting
fixture
installation
Warning
Warning
Warning
Warning: Failuretoinstallthefixtureproperlycouldresultinpersonalinjury.
Failuretoinstallthefixtureproperlycouldresultinpropertydamage.
:Prohibited
:Strictobservance
Caution:
Caution
Caution
Toinstallthefixturesafely《Readcarefullyandfollowalltheinstructionsintheguide》
Pleasefollowthefixturesʼindicationorspecificationforthedistanceofirradiatedarea.
(Causesofchangeinshape,changeincolorofirradiatedobjects)
Pleasecontactifyouarenotabletojudgewhetherinstallation
environmentissuitabletotheplacesornot.
Onlyqualifiedpersonmayworkonelectricwiringandequipment.(Causeofaccidents)
Besurepowersupplyvoltageiswithin±6%mentionedinratingplateortheguide.(Causesofshortlifeoflamps・electrification・fire)
Besureallthewiresandcodesarenotdamaged.(Causesoffalling・damage)
Pleasefollowthefixturesʼinstructionorthisguidetoinstallthefixtureandlamp.(Causesoffalling・electrification・fire)
Switchoffthepowerwheninstallingthelamp.(Causesofelectrification)
Donottouchthefixturewhenswitchisonorjustturnofftheswitchbecauseofhightemperature.
Donotputorcoverthefixturebyanycloths,papers,orinsulators.(Causesofnotlighting・fire)
Donotplaceanymetallicorflammableobjects.(Causeofelectrification・fire・brokenfixture)
Makesuretoinstallallthepartsoffixturesbesidesinstallationandmountingpartswillnottouchwithany
objectsbothinsideandoutsideofceilingsuchaslightingtrack,etc.(Causesoffalling・electrification・fire)
Donotdismountorremodelfixtures.(Causeofelectrification・fire・falling・brokenfixtures)
Donotoperatewithwethands.
Ifyousmellsmoke,seesmoke,orfindanythingunusual,pleaseturntheswitchoffandaskconstruction
companiestorepair.(Causeofelectrification・fire)
Makesuretheconstructionwillnotaffectanyfirepreventionsystemssuchassprinklerbyheatfromthefixture.
(Causesforimproperoperation)
Usealternatingcurrent.Pleasefollowratingplateoffixturesforpowersupplyfrequency.
(Causeofelectrification・fire)(50Hz・60Hzcommonuseforballastsandincandescentlampfixtures)
InstallationGuideLightingFixture
InstallationGuide
LightingFixture
Lamp
inputvoltage
inputcurrent
Driver
Soldseparately
Φ82
Ceilingcutout
kg
Weight
0.29
MSP-080F/20A/DL/3
SLICKJIAKARI
COB26W
35.6V
0.7AMAX
20cm〜
10cm
Insulator
InsulatorInsulator
−BLACK
+RED
Pleaseuseconstantcurrentdriver.
Question and Answer IconNeed help?

Do you have a question about the Modulex MSP-080F and is the answer not in the manual?

Overview

This document provides installation and safety guidelines for the ModuleX SLICK JIAKARI MSP-080F/20A/DL/3 lighting fixture, an indoor COB LED downlight.

Function Description

The ModuleX SLICK JIAKARI MSP-080F/20A/DL/3 is a recessed LED downlight designed for indoor use. It provides illumination from a COB (Chip-on-Board) LED, requiring a constant current driver for operation. The fixture is intended for general lighting applications in environments that meet specific temperature and humidity requirements, and where the mounting surface can adequately support its weight. Its design emphasizes safe installation and reliable performance, with detailed instructions for electrical wiring and physical mounting to prevent accidents and property damage.

Important Technical Specifications

  • Model: MSP-080F/20A/DL/3
  • Lamp Type: COB 26W
  • Input Voltage (Lamp): 35.6V
  • Input Current (Lamp): 0.7A MAX
  • Driver: Sold separately, requires a constant current driver.
  • Ceiling Cut Out Diameter: Φ82 mm
  • Fixture Weight: 0.29 kg
  • Dimensions: Φ92 mm (outer diameter), 280 mm (length including mounting springs), 8 mm (fixture thickness below ceiling), 9-25 mm (ceiling thickness range).
  • Operating Temperature Range: Above 0°C and below 35°C.
  • Power Supply Frequency: 50Hz - 60Hz (common use for ballasts and incandescent lamp fixtures).
  • Power Supply Voltage Tolerance: Within ±6% of the rating plate specification.
  • Screw Torque for Metal Fittings: 1.0 - 2.0 N·m.
  • Minimum Clearance from Insulator: 20cm (above fixture), 10cm (sides).

Usage Features

The MSP-080F/20A/DL/3 is designed for straightforward installation and safe operation, provided all guidelines are followed.

  • Indoor Use Only: Strictly for indoor environments, not suitable for outdoor or high-humidity conditions.
  • Specific Mounting Requirements: Must be installed on a flat, even, and stable ceiling surface that can support the fixture's weight. Not suitable for inclined surfaces, walls, or floors.
  • Temperature Sensitivity: Operates optimally between 0°C and 35°C. Avoid installation in areas with extreme temperatures, such as insulated ceilings without proper ventilation, or near heat sources like fires or air-conditioner machines.
  • Environmental Restrictions: Do not install in areas with high humidity, direct sunlight, excessive dust, corrosive gases, or where the fixture may be subject to vibration or shock.
  • Electrical Safety: Requires connection to an alternating current (AC) supply within the specified voltage and frequency range. Only qualified personnel should perform electrical wiring. Critical attention must be paid to correct polarity when connecting the driver (+ and -).
  • Physical Installation: Involves cutting an Φ82mm hole in the ceiling, installing a mounting frame, and securing it with screws. Metal fittings must be tightened to a torque of 1.0-2.0 N·m to prevent the fixture from falling. A safety wire must be installed to the mounting frame for added security.
  • Clearance Requirements: Maintain a minimum clearance of 20cm above the fixture and 10cm from the sides to any insulators or other objects within the ceiling space to prevent overheating and fire hazards.
  • Operational Safety: Always switch off power before installation or maintenance. Avoid touching the fixture when it is on or immediately after turning it off due to high temperatures. Do not cover the fixture with cloths, papers, or insulators, or place metallic/flammable objects near it.
  • Non-Modifiable Design: The fixture should not be disassembled or remodeled, as this can lead to electrification, fire, or breakage.
  • Wet Hands Prohibition: Do not operate the fixture with wet hands to prevent electrocution.
  • Emergency Procedure: If smoke, unusual smells, or any other abnormal conditions are observed, immediately switch off the power and contact construction companies for repair.
  • Fire Prevention System Consideration: Ensure that the heat generated by the fixture does not interfere with any fire prevention systems, such as sprinklers, to avoid improper operation.

Maintenance Features

The MSP-080F/20A/DL/3 requires minimal maintenance, primarily focused on ensuring safe and clean operation.

  • Cleaning: Use a clean, soft cloth to clean and maintain the inner side of the fixture body. This helps prevent dust accumulation which could affect performance or pose a fire risk.
  • Pre-Installation Inspection: Before installation, carefully inspect all wires and codes to ensure they are not damaged. Damaged wiring can lead to falling fixtures, electrification, or fire.
  • Secure Installation Check: Regularly ensure that all mounting parts, especially the metal fittings and safety wire, are securely installed and tightened to the specified torque. Loose parts can cause the fixture to fall.
  • Clearance Verification: Periodically check that no objects, such as lighting tracks or insulation, are touching the fixture inside or outside the ceiling, maintaining the required clearances.
  • Professional Repair: In case of any malfunction, unusual operation, or damage, do not attempt to repair the fixture yourself. Contact qualified construction companies or ModuleX for professional service.
  • Driver Compatibility: Ensure that the constant current driver used is compatible with the lamp's specifications (35.6V, 0.7A MAX) to prevent damage to the LED or driver.
  • Environmental Monitoring: Regularly assess the installation environment to ensure it continues to meet the specified temperature, humidity, and other environmental conditions to prolong the fixture's lifespan and ensure safe operation.

Modulex MSP-080F Specifications

General IconGeneral
BrandModulex
ModelMSP-080F
CategoryLight Fixture
LanguageEnglish