User Instructions
Modulift UK Ltd tel: +44(0)1202 621511 email: sales@modulift.com www.modulift.com
The Modulift Spreader is modular in length, and every spreader consists of 1 pair of End Units and
Drop Links, with intermediate struts that can be bolted into the assembly to achieve dierent spans.
Personnel using this system should be suitably trained, competent and have a clear
understanding of Safe Slinging procedures.
The use of Modulift equipment must be in accordance with the procedures laid down in
‘Lifting Operations and Lifting Equipment Regulations 1998’ (LOLER).
Never exceed stated WLL – Adhere to WLL in Table 2 for particular sling angle used.
The top sling length is critical to the safe use of the spreader – Adhere to Table 2.
Ensure Drop Links hang down, and smaller shackles are connected to bottom hole of Drop Link.
Do not under any circumstances hang load(s) from the tube or anges – the spreader is designed for
axial compression, not bending.
WARNING!
MOD 12
MOD 12 has an assembled span ranging from 0.5 metres to 6.5 metres in 0.25 metre increments.
MOD 12 Beam Specication
Rated at 12 tonnes WLL at 4.75 metres span
(30° STV). See Load Table for WLL at longer spans.
‘Sling to Vertical’ angle, β, 45 degrees or less.
End Units & Drop Links are rated at 6 tonnes WLL each (12 tonnes combined capacity).
Bolt tightening torque: 90Nm. Spanner size required: 19mm.
Recommended additional equipment: Torque Wrench, Podger Spanner and Ring Spanner.
P1 P2P3–P7
Span
β
P8
P9 P10
β = Sling to vertical angle
Strut
Drop link
End unit sub-assy
Larger shackle
Smaller shackle
Drop link
Table 1 – Component List
Part Ref. Description Weight/item
P1 End Unit 6kg
P2 Drop Link 1.3kg
P3 1.5m Strut 19kg
P4 1.0m Strut 14kg
P5 0.75m Strut 11kg
P6 0.5m Strut 8kg
P7 0.25m Strut 6kg
P8
8.5t Shackle
2.5kg
P9
6.5t Shackle
1.5kg
P10
M12 x 35, Grade 8.8, HT Bolts, Nuts & Washers
Fig. 1 – Typical Spreader Assembly