EasyManua.ls Logo

Momento DELTA SIGMA User Manual

Momento DELTA SIGMA
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.momento.se
OPERATORS MANUAL
DELTA SIGMA Ultrasonic instrument
Question and Answer IconNeed help?

Do you have a question about the Momento DELTA SIGMA and is the answer not in the manual?

Momento DELTA SIGMA Specifications

General IconGeneral
BrandMomento
ModelDELTA SIGMA
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction

Delta Sigma Instrument Overview

Overview of the Delta Sigma ultrasonic time-of-flight measurement device, its features, and connectivity.

Operation of the Delta Sigma

Device Overview and Ports

Details the physical components and ports of the Delta Sigma ultrasonic instrument.

Project and Bolt Data Files

Explains the structure and purpose of Project and Bolt Type files for organizing measurements.

Start-Up Screen and Initial Charging

Guides users on initial charging and the operation of the Delta Sigma start-up screen.

Setup Screen Options

Details the functions available in the SETUP screen, including backup, maintenance, security, and options.

Measurement Process

Guides users through selecting projects and starting the bolt measurement process.

Creating a New Project

Step-by-step instructions for creating a new project, entering operator details, and setting units.

Configuring Bolt Types and Properties

Procedure for creating and configuring bolt types, including material properties and measurement parameters.

Setting Measurement Parameters

Explains setting limits, velocity factors, and pulse cycles for bolt measurements.

Measuring Bolts

Detailed steps for attaching the transducer and performing bolt measurements, including couplant application.

Signal Acquisition and Scope Usage

Guidance on interpreting echo signals, using the scope function, and handling signal acquisition issues.

Elongation Measurement

How to perform and record elongation measurements after initial bolt tightening.

Operational Discussion on Signal Interpretation

Discusses signal amplitude, AGC, and handling complex bolt end features during measurement.

Measuring a New Bolt

Steps for reading a new bolt or adding a new bolt to the sequence after completing a measurement.

Exporting Data to PC

Instructions for exporting measurement data in Excel format to a PC via USB.

Data Files and Structure

Details the $DATAFILES folder structure and contents for CSV and scope trace data.

Opening CSV Files in Excel

Steps for opening exported CSV files in Microsoft Excel for analysis.

System Data Backup and Transfer

Procedure for backing up and transferring project and bolt type data to a PC or other DS units.

Restoring System Data

Reverse procedure for restoring project and bolt type data from a PC backup to the DS unit.

Important Operation Notes

Covers common operational issues like 'No Echo' and bolt length display discrepancies.

Specifications and Features

Technical Details: Batteries and Features

Information on battery specifications, operational time, and additional features like real-time clock and sleep mode.

Appendix A: Material Properties

Appendix B: Glue-On Transducer Instructions

Appendix C: Calculation Setup

Appendix D: Units and Geometric Properties

Appendix E: Estimating Load Factor

Worked Example for Load Factor

Demonstrates the calculation of Load Factor using metric units for a specific bolted joint.

Appendix F: Transducer Specifications