Do you have a question about the Monaghan AEROCHAMBER PLUS Z STAT aVHC and is the answer not in the manual?
Remove inhaler and mouthpiece caps before use.
Shake the inhaler before attaching it to the chamber.
Insert the inhaler into the back of the chamber securely.
Apply the mouthpiece or mask to the face.
Press inhaler, breathe slowly, hold for 5-10s or breathe 2-3 times.
Repeat steps 2 to 5 as prescribed for effective use.
Remove the back piece of the chamber for cleaning.
Soak 15 min in soapy water, rinse or dishwasher.
Shake out excess water and dry the chamber vertically.
Reassemble the chamber after it has been cleaned and dried.
The Monaghan AeroChamber Plus® Z STAT® aVHC is a valved holding chamber designed to improve the delivery of medication from metered-dose inhalers (MDIs) to the lungs. It is intended for use by individuals who use an inhaler and provides better control over medication delivery compared to using an inhaler alone with poor technique.
The primary function of the AeroChamber Plus® Z STAT® aVHC is to act as a spacer between the MDI and the patient's mouth or face. When the MDI is actuated into the chamber, the medication is suspended within the chamber, allowing the patient to inhale it slowly and deeply. This process helps to reduce the amount of medication that deposits in the mouth and throat, increasing the amount that reaches the lungs. The valved design ensures that medication remains in the chamber until inhaled, preventing it from escaping prematurely. The Z STAT® feature likely refers to an antistatic property, which helps to prevent medication from sticking to the walls of the chamber, ensuring more consistent and effective delivery.
The device is available in various configurations to suit different patient needs, including:
The chamber is designed to be compatible with most standard metered-dose inhalers (MDIs). It is explicitly stated that the device has not been made (or manufactured) with BPA (Bisphenol A) or Natural Rubber Latex, which is an important consideration for patients with allergies or sensitivities to these materials.
The quick start guide outlines a simple, step-by-step process for using the AeroChamber Plus® Z STAT® aVHC:
The visual aids in the guide clearly differentiate between using an inhaler alone with poor technique (showing medication depositing in the throat) and using an inhaler with a valved holding chamber (showing medication reaching the lungs).
The quick start guide also provides instructions for cleaning the chamber to ensure hygiene and proper function:
For more detailed cleaning instructions, including dishwasher compatibility, users are advised to refer to the complete instructions packaged with the device. The dishwasher instructions are specifically mentioned as being available in the full manual. Regular cleaning is crucial to prevent medication residue buildup, which could affect the device's performance and hygiene.
In summary, the Monaghan AeroChamber Plus® Z STAT® aVHC is a user-friendly, latex- and BPA-free valved holding chamber designed to optimize MDI medication delivery to the lungs, available in various sizes to accommodate different patient populations, and easily maintained through simple cleaning procedures.
| Brand | Monaghan |
|---|---|
| Model | AEROCHAMBER PLUS Z STAT aVHC |
| Category | Medical Equipment |
| Language | English |