APPLICATION
This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft. In off-set
PERFORMANCE
installations, friction losses in the suction pipe must be taken into
consideration.
Total Head in Feet
Pump Pump Solids 30 40 50 60 70 80 90
Model Size Handling Capacity in U.S. Gallons per Minute
TSP 2 2” x 2” 1 1/8” 198 194 180 145 110 75 40
TSP 3 3” x 3” 1 1/2” 318 265 172 98 42
TSP 4 4” x 4” 2” 616 500 400 280 190 120 45
BASED ON 5’ SUCTION LIFT.
NOTE: This trash pump can handle pumping stones, leaves,
mud and other debris of sizes up to the listed solids handling for
the pump and up to 25% of the flow by volume.
Total Head in Metres
Pump 9 12 15 18.5 21.5 23.5 27.5
Model Capacity in Litres per Minute
TSP 2 750 735 680 550 415 285 150
TSP 3 1205 1005 650 370 160
TSP 4 2330 1890 1515 1060 720 455 170