EasyManua.ls Logo

Monarch TSP 3 User Manual

Monarch TSP 3
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OWNER'S
MANUAL
TSP SERIES
Self Priming Trash Pumps
PumpBiz.com
200162R3 0402
SAFETY WARNINGS
BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
CAUTION
DO NOT OPERATE THIS PUMP DRY!
Review instructions before operating.
Wear ear protection to reduce objectionable noise.
__________________________________________________
WARNING
Turn off power before servicing.
If fuel is spilled, avoid creating any source of ignition until the
fuel vapors have been cleaned up and removed.
APPLICATION
This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft. In off-set
PERFORMANCE
installations, friction losses in the suction pipe must be taken into
consideration.
Total Head in Feet
Pump Pump Solids 30 40 50 60 70 80 90
Model Size Handling Capacity in U.S. Gallons per Minute
TSP 2 2” x 2” 1 1/8” 198 194 180 145 110 75 40
TSP 3 3” x 3” 1 1/2” 318 265 172 98 42
TSP 4 4” x 4” 2” 616 500 400 280 190 120 45
BASED ON 5’ SUCTION LIFT.
NOTE: This trash pump can handle pumping stones, leaves,
mud and other debris of sizes up to the listed solids handling for
the pump and up to 25% of the flow by volume.
Total Head in Metres
Pump 9 12 15 18.5 21.5 23.5 27.5
Model Capacity in Litres per Minute
TSP 2 750 735 680 550 415 285 150
TSP 3 1205 1005 650 370 160
TSP 4 2330 1890 1515 1060 720 455 170
SAFETY
CAREFULLY READ THESE SAFETY
MESSAGES IN THIS MANUAL AND
ON PUMP.
Question and Answer IconNeed help?

Do you have a question about the Monarch TSP 3 and is the answer not in the manual?

Monarch TSP 3 Specifications

General IconGeneral
BrandMonarch
ModelTSP 3
CategoryWater Pump
LanguageEnglish

Summary

Safety Warnings and Precautions

General Operation Safety

Read manual, follow rules, and avoid dry operation; wear ear protection.

Servicing and Fuel Safety

Turn off power before servicing and avoid ignition sources with spilled fuel.

Application and Performance

Pump Application Limits

Suitable for vertical lift up to 25 ft; consider suction pipe friction losses.

Solids Handling Capability

Handles debris up to specified sizes and 25% of flow volume.

Installation Guidelines

Pump Location Requirements

Install in a dry, well-ventilated location with adequate drainage and level foundation.

Ventilation Caution

Ensure adequate ventilation to prevent asphyxiation.

Suction Hose Specifications

Use clean, non-collapsible hose of pump suction pipe diameter; increase size for long lengths.

Pump Priming Operations

Critical Priming Warning

Never run the pump dry; this will permanently damage the seal and impeller.

Non-Pressurized Priming

Fill pump casing with water; replace plug and start engine. Avoid vapor lock on long lines.

Pressurized Priming

Use discharge check valve and air bleeder; fill casing with water and start engine.

Pump Maintenance Procedures

Covers unclogging, draining for freezing, and proper storage of the pump.

Maintenance Procedures

Lubrication Requirements

The pump itself requires no lubrication; refer to engine manual for engine lubrication.

Replacing Seals and Components

Detailed steps for disassembling and reassembling pump components for seal replacement.

Reassembly Caution

Ensure impeller rotates freely within the volute after dismantling and reassembly.

Troubleshooting Guide

No Discharge Troubleshooting

Addresses issues like improper priming, low speed, high suction lift, or discharge too high.

Reduced Capacity Troubleshooting

Covers air leaks, clogged impeller, low speed, or excessive suction lift.

Pump Loses Prime Troubleshooting

Identifies causes like air leaks, gas in liquid, loose seals, or faulty check valve.

Excessive Power Consumption

Troubleshoots issues related to high speed or high liquid specific gravity/viscosity.

Noise Troubleshooting

Addresses problems with piping support or cavitation.

Limited Warranty Information

Warranty Coverage and Duration

One-year warranty for defects in material or workmanship; transportation costs borne by purchaser.

Warranty Service Procedure

Contact nearest Monarch Industries Authorized Service Depot for warranty service.

Warranty Disclaimers

No other express warranties; implied warranties limited to one year.

Repair Parts List

Applicable Pump Series

List covers TSP 3, 3RF, 3H, 3HRF, 3D, and TSP-3ICRF self-priming trash pumps.

Parts Ordering Notes

Specific notes for ordering replacement parts, especially for Type A volute/rear casing.