Eco Convection Ovens | 4/5/7/10-Tray | Steam Quick Start Guide
12
MONO FG1BX-UK-QSG-0100 | Rev. B23 (July 2023)
Installation
Power supply
WARNING An electrical socket must be protected by a 30mA-rated Type ‘A’ Residual Current
Device (RCD) before installation and commissioning of the oven.
Always fit a wall-mountable isolator switch to isolate the oven entirely from the
electrical supply in an emergency. The isolator must be visible, labelled as an
emergency shutdown device, and easily accessible.
Check that the electrical requirements on the oven’s information plate match the
supply before connecting the power cable and turning the power on for the first time.
Figure 2: Main power supply connections
NOTE L2 and L3 are for three-phase installations only.
See the Specifications section for electrical specifications.