Performance Data Sheet
Model: GE RPWFE
UseReplacement Cartridge RPWFE.
Theconcentration of the indicated substances in water entering the system was reduced to a concentration lessthan or equal to the permissible
limit for water leaving the system as specified in NSF/ANSIStandard/42 and Standard 53.Systemtested and certified by NSFInternational against
NSF/ANSIStandard/42 and Standard 53for the reduction of substances listed below.
Capacity 170 Gallons (643.5 Liters).
Substance TeSte d
for Reduction Average Influent
0.278 m( 0.300 m(
*Basedon the use of Cryptosporidium parvum oocysts.
Contaminant Reduction Determined
NSFspecif Avg%
Challenge Concentration Reduction
97.4%
99.0%
99.99%
9/4.4%
96.4%
98.8%
99.99%
99.3%
98.3%
91%
88.3 % %
99%
99.8%
93.5%
99.9%
97.7%
py NSF testing.
Average Product
Water
Concentration
0.05 mg/L
71,850 pts/ml
<1 MFL
0.0005 mg/L
0.001 mg/L
0.001 mg/L
3 cyst/L
0.001 mg/L
0.002 mg/L
0.0003 mg/L
0.0007 mg/L
0.00002 mg/L
0.0005 mg/L
0.001 mg/L
0.0001 mg/L
0.0015 mg/L
Max Permissible
Product Water
Concentration
N/A
NSF Reduction NSF
Requirements
_>50%
Test Report
J-00102044
N/A 285% J-00106249
299%
N/A
N/A
N/A
299.95%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
295%
N/A
0.003 mg/L
0.005 mg/L
0.0/4mg/L
N/A
0.0!0 mg/L
0.0!0 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.075 mg/L
0.003 mg/L
0.07 mg/L
N/A
J-00102069
J-00102058
J-00102065
J-00102059
J-00102057
J-00102052
J-00102053
J-00102054
J-00104087
J-00102063
J-00102067
J-00102061
J-00102064
J-00102070
The following pharmaceutical reduction claims have not been certified by NSFInternational. Claims tested and verified
by independent laboratory:
= I I I HaxPermissible
Substance I I NSFsPecified Avg % Average P[oduct Water [ Product Water I NSF
Reduction Average Influent Challenge Concentration Reduction Concentration ' Concentration Test Report
1088 ng/L N/A 99.5% 5.0 ng/L N/A J-00103221
845 n,g/L N/A 99.4% 5.0 ng/L N/A J-00103221
898 ng/L N/A 98.8% 9.9 ng/L N/A J-00103726
945 ng/L N/A 99.4% 5.5 n,g/L N/A J-00103727
403 ng/L N/A 99.5% 2.0 ng/L N/A J-00103221
Application Guidelines/Water Supply Parameters
Service Flow Water Pressure (172- 827 kPa)
Water SU_ Water Temperature ] 33 ° F- 100° F _6_ : _ C)
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Hanual for Warranty information.
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWFE. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
/_WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with woter that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disinfected water that may contain filterable
cysts. EPA Establishment Number 070595-MEX-O01.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure optimal filter
performance:
Read and follow use instructions before installation and use of this system.
Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (827 kPa). Ifyour water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain howto checkyour water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you a re uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100 ° F (38° C).
Protect filter from freezing. Drain filter when temperatures drop
below 33OF(0.6°C).
Change the disposable filter cartridge every six months or sooner if you observe
a noticeable reduction in water flow rate.
Failure to replace the disposable filter cartridge at recommended intervals may
lead to reduced filter performance and cracks in the filter housing, causing water
leakage or flooding.
(_ [ Tested and certified by NSFInternational
| against NSF/ANSIStandard 42and Standard 53
/ in model GERPWF and GERPWFEfol the
/ reduction of the claims specified on the
RE_EE_NT Jpeffo .......... data sfieet
18
RPWFE