1.INTRODUCTION
This manual provides instructions and procedures necessary to install,
operate and troubleshoot the Moog 641 Series Proportional Control Valve.
Troubleshooting instructions are outlined so that the specific component(s)
suspected of failure can be identified.
2. OPERATION
The Moog 641 Series proportional control valves are suitable for open
and closed loop position and velocity control systems where accelerations need
to be regulated.The 641 can be used like a directional solenoid valve or a
proportional valve while controlling ram or motor acceleration, deceleration
and velocity.
The 641 Series valves are two-stage devices consisting of a double nozzle-
flapper pilot stage and a sliding spool main stage.The position of the main stage
spool is measured by a non-contacting position transducer.On-board integrated
electronics provide closed-loop position control of the main stage spool.
The operation of the 641 Series valve is controlled by an electrical
command signal (VQS) provided to the integrated control electronics which
drives the pilot stage coils.The current sent from the electronics causes the
flapper to move toward one nozzle,diverting the pilot stage flow to one end of
the spool.The position transducer measures the position of the spool (VLI) and
produces a feedback voltage which is directed back to the control amplifier and
compared to the command voltage.The control amplifier then drives the pilot
stage until the command voltage and feedback voltage are equal,centering the
flapper between the nozzles which holds the spool at a position proportional to
the command signal.
m
641 Series Installation and
Operation Instruction
Proportional Control Valve
SINGLE STAGE
PILOT VALVE
SPOOL
FLAPPER
POSITION
CONTROL
AMPLIFIER
SPOOL POSITION
TRANSDUCER
(LVDT)
OSCILLATOR-
DEMODULATOR
MAIN STAGE
INLET ORIFICE
NOZZLE
PATB
V
QS
V
LI
ELECTROHYDRAULIC VALVE CUT-AWAY
CAUTION
DISASSEMBLY, MAINTENANCE,OR REPAIR OTHER THAN IN ACCORDANCE WITH THE
INSTRUCTIONS HEREIN OR OTHER SPECIFIC WRITTEN DIRECTIONS FROM MOOG WILL
INVALIDATE MOOG’S OBLIGATIONS UNDER ITS WARRANTY.
Figure 1 Moog Series 641