Remove condensed water…
…out of tank.
Procedure:
1. Close hand-valve for compressed air at
air outlet.
2. Release air out of tank by
Hand Air-Pistol. (Is in accessory-Package)
2. Release all compressed air out of tank
by:
Hand-valve-lever turn 45 degree.
Attention:
Do not tilt the compressor more than 45
degree. If tilted more than 45 degree turn in
normal position and let rest for app. 1 hour to
allow oil to move in place - before new start of
binding..
Renew of Oil
Compressor-oil should be renewed every 12
month.
Take cap off oil-outlet.
Tilt compressor and drain oil into a can.
Refill 100 ccm oil with filling bottle to be filled
with compressor-oil for full filling.
1 bottle of 100 ccm oil and a refilling-bottle is
in the package of compressor
Air-Filter.
Air In-Let is originally sealed by cap.
Remove cap and keep it for future use.
Put on the Air Filter (delivered with
accessory of Compressor) by sliding it
on the inlet-tube-top.
For next transport of compressor take
filter off and put cap on again. Otherwise
oil might leak out of inlet whilst transport
and/or do not tilt the compressor more
than 45 degree. If tilted more than 45
degree turn in normal position and let
rest for app. 1 hour to allow oil to move in
place - before new start of binding..