DK ENG
Installation of woodburning stoves must be safe and legal.
The installation must conform standard CAN/CSA-B365, Installation Code For
Solid-Fuel-Burning Appliances and Equipment
Make-shift compromises during installation can have consequences, the Installation of
the woodburning stoves must be safe and legal.
If your Morsø stove is not installed correctly, it may cause a house re. To reduce the risk
of re, the installation instructions must be followed carefully. Contact the local building
ocials about restrictions and installation inspection in your are
Before you start installing your stove, make sure that:
- The stove and chimney connection are placed far enough from combustible materials to
meet all clearance requirements.
- The oor protection must be adequate and must be made correctly according to the
requirements.
All neccessary approvals are needed from the local building ocials.
The data plate, which is located on the back of the stove, provides information regarding safety
testing information, name of certied testing laboratory, and installation requirements.
Installation requirements vary in dierent districts, and the local building ocials have the nal
authorization to approve your installation. You should discuss the installation with them before
beginning. Please ask your dealer for further information.
Do not connect to any air distribution duct or system.
Important: If the installation instructions are not followed carefully, it may cause dan-
gerous situations like chimney - and house res. Follow the instructions carefully and
do not deviate from them as it may cause injuries to people or property.
1.1 Checking loose parts in the stove
After unpacking, check that the re bricks are rmly in position and have not shifted in tran-
sit. Check also that the air control works freely.
Before starting the initial re, make sure that the baes is placed correctly.
Standard Accessories
A Morsø glove and ceramic ue connection gasket are standard accessories that usually can
be found in the ashpan or rebox area.
1.2 The chimney / ue system
Note that the ue system must be independently secured and must not rely on the stove
for support.
The stove must not be connected to a chimney ue serving any other appliance.
(Several ues may run up a single chimney stack; use one ueway per appliance).
Use a code-approved masonry chimney with a ue liner or listed type HT factory-built
chimney
High Temperature (H.T.) Chimney Standard UL-103-1985 (2100º F.) or a code-approved
masonry chimney with ue liner for the USA, and High Temperature (650ºC) Standard
ULC S-629 for Canada.
The internal dimensions of the chimney connector and chimney must not be less than 6 inch-
es diameter (or equivalent cross section), and should not be signicantly larger than this. Too
large a section will tend to allow the ue gases to cool excessively, causing sluggishness or
unpredictability in the stove’s performance.
We recommend the length of the chimney system should be at least 16 feet (not required)
above the stove in normal domestic situations, measured from the ue collar to the top of
the chimney.
Local conditions like for example - roof constructions, large trees nearby and high altitude,
may inuence the chimney draft and height. Therefore, contact the local professional chim-
ney sweep or your Morsø dealer.