Report No.: 300-ELAB-2381-EPA
Date: 06.09.2019
Initials: JSA/MGJN
Page 4 of 25
300-ELAB-2381-EPA
General
This report concerns testing of a free-standing stove of landscape format, type Morsø 6100B
There is a CBI version of the report holding all of the 29 annexes. In the non-CBI report, annex 12
(DTI test procedure), annex 22 (Assembly drawings) and annex 23 (parts drawings are excluded.
Please find the full list of annexes in chapter 13.
Scope of testing
The appliance was tested to demonstrate compliance with the NSPS 2020 limits, using the
alternative Cordwood test method broadly accepted by the administrator. Please find the letter of
acceptance enclosed in appendix 1
Site
Testing was accomplished by Danish Technological Institute, Kongsvangallé 29, DK-8000 Aarhus C,
Denmark in accordance to DTI’s accredited EPA test procedure ELAB-PP-BR-15 (CBI information).
The test procedure is amended in appendix 12 to the CBI report variant, but left out in the non-CBI
report variant
Participants
DTI staff
Testing in the laboratory was accomplished by:
- Jes Sig Andersen, Senior Specialist (lead)
- Rene Lyngsø Hvidberg, Senior Specialist (trainee)
Client staff
The test work was witnessed by:
- Frank Juel Nielsen, Morsø Jernstøberi A/S
Test specimen
The stove was manufactured by:
The stove weighs 105 kg.
The stove is not equipped with a catalyst. The portrait type of firebox is of ellipsoidal shape
The effective firebox volume used for fuel load calculation is 0.0143 m
3
(0.5050ft
3
)
Please find the firebox dimensions in detail in the Main drawing 6100-254, dated 6. May 2019 in
appendix 22