1
These downow furnaces are specially designed for
installation in manufactured, (mobile home) or modular
housing. Four heat capacities and three blower choices
handle heating and cooling (up to 5 tons) in any climate.
All blowers are multi-speed to ne tune airow to the
home ensuring quiet operation, high operating efciency
and comfort.
FEATURES
HEATING ONLY or HEATING & A/C UNITS
ELECTRONIC IGNITION
SEALED COMBUSTION VENTING
ALUMINIZED STEEL HEAT EXCHANGER
ZERO CLEARANCE TO CONSTRUCTION
BUILT-IN ‘A’ COIL CABINET – 25-1/2”H ( C cab.)
SHORTER A/C FURNACE-ONLY 77-1/2”H
HOGS HAIR WASHABLE AIR FILTERS
CONTOURED WHITE DOOR PANELS
Model No.
G18D060AH2AA
G18D070AH2AA G18D077AH2AA
G18D090AH2AA G18D060CA3AA
G18D070CA3AA G18D077CA3AA G18D090CA3AA G18D060CA5AA G18D070CA5AA G18D077CA5AA
G18D090CA5AA
Input, BTUH 60,000 70,000 77,000 90,000 60,000 70,000 77,000 90,000 60,000 70,000 77,000 90,000
Output, BTUH 48,000 56,000 61,600 72,000 48,000 56,000 61,600 72,000 48,000 56,000 61,600 72,000
AFUE, % 80 80 80 80 80 80 80 80 80 80 80 80
With A-Coil Cabinet YES YES YES YES YES YES YES YES YES YES YES YES
Ignition Type Auto-Elect Auto-Elect Auto-Elect Auto-elect Auto-Elect Auto-Elect Auto-Elect Auto-elect Auto-Elect Auto-Elect Auto-Elect Auto-elect
Air Temperature Rise, Range - F
40-70 40-70 40-70 45-75 40-70 40-70 40-70 45-75 40-70 40-70 40-70 45-75
Designed Max Outlet Air Temp-F
170 170 170 175 170 170 170 175 170 170 170 175
Natural Gas Orice Size 27 22 19 17 27 22 19 17 27 22 19 17
Propane (LP) Gas Orice Size
44 42 41 37 44 42 41 37 44 42 41 37
Blower-Heat or Heat/Cool 10 X 8, 1/4 HP, 2 SPD 10 X 8, 1/3 HP, 3 SPD 10 X 8, 3/4 HP, 4 SPD
Max. External SP (Duct), In.
W.C. 0.3
Fuel
Natural Gas (Factory Equipped) - LP Orice Furnished
High Altitude For elevations above 2,000 feet, reduce input 4% for each 1,000 ft. elevation above sea level
Furnace Flue Pipe Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof
Gas Connection 1/2" FPT
Electric Service 115 VAC, 60 Hz, 1 PH
Fuse or Circuit Breaker 15 Amp
Thermostat Circuit 24 VAC, 60 Hz, 40VA
Filters 2 - 16" X 20" X 1"
SEALED COMBUSTION
DOWNFLOW GAS FURNACE
SIZES: 60, 70, 77, 90
M ODELS : G18D SERIES
CAUTION: READ ALL SAFETY GUIDES
BEFORE INSTALLING THIS GUIDE
TECHNICAL GUIDE
“A” Cabinet “C” Cabinet
80 AFUE - AUTOMATIC HOT SURFACE IGNITION