Reduce risk of injury/damage by observing warnings and instructions. Keep work area clean, maintain tool.
Always wear proper personal protection, including face shield and gloves, to prevent injury.
Ensure stud welder is connected to a properly grounded outlet and avoid contact with grounded surfaces.
Avoid operating in explosive atmospheres; sparks can ignite flammable materials. Use in well-ventilated areas.
The Magna Stitcher turns a stud welder into a plastic repair tool for various automotive parts.
Install the Magna Stitcher on the stud welder by seating it firmly against the insulator.
Prepare the repair area by removing all dirt, oil, and dust for optimal results.
Insert stake, heat briefly to melt plastic, allow to sink halfway, twist to lock, and let cool.
Use an S-Shaped Magna-Stake for flat areas, inserting and spacing stakes 1/2 to 3/4 inch apart.
Use an M-Shaped Magna-Stake for tabs and thin sections, adding stakes as needed for strength.
Use a V-Shaped Magna-Stake for inside corners, inserting and spacing stakes 1/2 to 3/4 inch apart.
Use a W-Shaped Magna-Stake for outside corners, inserting and spacing stakes 1/2 to 3/4 inch apart.
Details on S, M, V, and W-shaped Magna-Stakes for different repair applications.
Identifies the Magna-Stitcher Repair Tool (MS-1) and Replacement Thumb Screw (M1003).
Covers defects in workmanship/material for one year; excludes normal wear and misuse.