Do you have a question about the motortronics VMX-Synergy Plus and is the answer not in the manual?
Category | DC Drives |
---|---|
Regulation | Closed Loop |
Speed Regulation | ±0.1% of base speed |
Communication | Modbus, Ethernet, Profibus |
Diagnostics | LED Indicators |
Protection | Overcurrent, Overvoltage, Overtemperature |
Enclosure Rating | NEMA 1 |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -20°C to 60°C |
Humidity | 5 to 95% non-condensing |
Altitude | Up to 1000m |
Input Voltage | 240/480 VAC |
Provides essential safety notices and symbols used in the manual.
Details on how to mount the unit securely to a flat, vertical surface.
Explains the need for ventilation and provides a formula for calculating fan requirements.
Provides dimensional data and weights for different unit sizes.
Lists critical warnings regarding isolation, control supply, fuse protection, and general safety.
Provides detailed descriptions for each terminal, including function, programmability, and ratings.
Illustrates wiring diagrams for three-wire control with different supply voltages.
Lists electrical ratings (Ie, kW, FLA, HP) for various models and supply voltages.
Provides sizing guidance for In-Line and In-Delta motor connections based on trip class.
Lists recommended fuses and circuit breakers for Size 1 units for short circuit protection.
Lists recommended fuses and circuit breakers for Size 2 and 3 units for short circuit protection.
Introduces how to configure the soft starter using its touchscreen, remote, or PLC.
Critical safety warning about potential risks of using the Auto Reset function.
Timing diagram illustrating Auto Reset with a two-wire control during 3-phase supply loss.
Lists parameters available within the 'Advanced' category of the touchscreen interface.
Details parameters for digital and analog inputs/outputs in the I/O menu.
Lists parameters available for monitoring motor and system status in the Monitor menu.
Details parameters for logging trip events, start/stop currents, and temperatures.
Covers device settings such as firmware updates, date, time, language, and network configuration.
Parameters for automatic adjustment of start/stop behavior and ramp profiles.
Parameters related to start time, pedestal, current limits, and kick start.
Parameters for controlling the soft stop behavior, including time, pedestal, and current limits.
Parameters for overload, low current, shearpin, and other motor protection features.
Parameters for configuring the intelligent Energy Recovery System (iERS).
Setting for selecting the control interface: Touchscreen, Terminal, Modbus.
Setting for selecting the firing mode (In-Line or In-Delta).
Parameters for compatibility with older applications or features.
Configuration for controlling the unit based on main contactor status.
Settings for hand/auto selection and its impact on control method.
Configuration parameters for the Auto Reset feature, including delay and attempts.
Lists and describes various trip codes, their causes, and recommended actions.
Details Modbus RTU serial communication setup, connection, and features.
Explains Modbus register aliasing for easier PLC programming and data access.
Provides instructions for updating VMX-Synergy Plus firmware via USB.
Details the procedure for remote installation of the touchscreen.