Important rules and hints for installation, function, and usage. Safety and warning instructions must be observed.
Unit intended for industrial machines. Non-conforming usage is user's responsibility. Not for explosion-proof areas.
Device installation within permissible temperature range, ensuring ventilation. Disconnect all voltage sources before installation/maintenance.
Measures to minimize electromagnetic interference: shielded cables, proper grounding, and mounting.
Cleaning the front with a soft, damp cloth. No maintenance during normal operation. Unauthorized repair is prohibited.
Unit is versatile, configurable in parameter menu. Modes include SPEED, PROCESS TIME, TIMER, COUNTER, VELOCITY.
Diagram illustrating the functional blocks and data flow of the touchMATRIX® indicator.
Unit accepts DC supply from 18 to 30 V. GND terminals are interconnected.
Terminals 3 and 4 provide auxiliary output for sensors/encoders. Voltage depends on power supply.
Unit provides two inputs for HTL signals. Characteristics (PNP, NPN, Namur, Tri-State) configurable.
Unit provides two pulse inputs for HTL/RS422 signals. Characteristics configurable in GENERAL MENU.
Three control inputs with HTL PNP characteristics. Programmable functions include reset, display switching, and locking.
16-bit analog output available. Configurable for voltage (-10...+10 V) or current (0...20 mA / 4...20 mA).
RS232 or RS485 interface for setup, parameter modification, and data readout.
Four control outputs are fast PNP outputs. Switching conditions set in PRESELECTION MENU.
Unit accepts AC supply from 115 to 230 V. Can also be supplied with DC voltage.
Two potential-free changeover relay outputs. Switching conditions set in PRESELECTION MENU.
Describes how to edit parameters via touchscreen: start setup, menu selection, parameter selection, and editing.
Details the various display screens available during operation, such as unit/status bar, counter/timer, two-line, large display, and command keys.
Lists and explains common error messages displayed on the unit, such as maximum/minimum display value errors.
Parameter settings for OPERATIONAL MODE, ENCODER PROPERTIES, ENCODER SUPPLY, COUNTING DIRECTION, SCALE UNITS, LINEARIZATION MODE, PIN PRESELECTION, PIN PARAMETER, BACK UP MEMORY, FACTORY SETTINGS.
Defines operation as speed indicator, tachometer, or frequency meter. Parameters include DISPLAY VALUE, BASE FREQUENCY, DECIMAL POINT, SAMPLING TIME, WAIT TIME, STANDSTILL TIME, AVERAGE FILTER, FOR/REV DETECTION.
Defines operation as baking or processing time indicator. Parameters include DISPLAY FORMAT, DISPLAY VALUE, BASE FREQUENCY, SAMPLING TIME, WAIT TIME, STANDSTILL TIME, AVERAGE FILTER.
Defines operation as timer or stopwatch. Parameters include TIME BASE, START/STOP, AUTO RESET, LATCH FUNCTION, SET VALUE, INC / DEC MODE, TOTAL TIME MODE, TOTAL TIME SET VALUE.
Defines operation as position indicator, impulse counting, sum, difference, or up-down counter. Parameters include COUNT MODE, FACTOR, SET VALUE, DECIMAL POINT, BATCH / TOTAL MODE, ROUND LOOP VALUE.
Defines operation as runtime measurement for speed. Parameters include START/STOP, DISPLAY VALUE, BASE TIME, DECIMAL POINT, WAIT TIME, STANDSTILL TIME.
Sets preselection values or switching points for options CO, AO, or RL. Includes PRESELECTION 1 to 4.
Defines reference source, switching conditions (MODE 1), hysteresis, pulse time, output target, polarity, lock, startup delay, and event color for preselection 1.
Defines reference source, switching conditions (MODE 2), hysteresis, pulse time, output target, polarity, lock, startup delay, and event color for preselection 2.
Defines reference source, switching conditions (MODE 3), hysteresis, pulse time, output target, polarity, lock, startup delay, and event color for preselection 3.
Defines reference source, switching conditions (MODE 4), hysteresis, pulse time, output target, polarity, lock, startup delay, and event color for preselection 4.
Sets serial interface parameters: UNIT NUMBER, SERIAL BAUD RATE, SERIAL FORMAT, SERIAL INIT, SERIAL PROTOCOL, SERIAL TIMER, SERIAL VALUE, MODBUS.
Configures analog output: ANALOG SOURCE, ANALOG FORMAT, ANALOG START, ANALOG END, ANALOG GAIN, ANALOG OFFSET.
Assigns functions to control inputs (INPUT 1 ACTION, INPUT 2 ACTION, INPUT 3 ACTION) and configures input characteristics (INPUT 1 CONFIG, etc.).
Configures display settings: SOURCE DUAL TOP/DOWN, COLOR, BRIGHTNESS, CONTRAST, SCREEN SAVER, UP-DATE-TIME, FONT, START DISPLAY, LARGE DISPLAY.
Defines linearization points (P1(X)-P24(X) and P1(Y)-P24(Y)) for non-linear signal conversion.
Details how to request data transmission via serial interface using the Drivecom protocol.
Describes Modbus RTU Slave functionality, including parameter setting and Modbus communication.
Lists all parameters with their serial codes, min/max values, and default settings for quick reference.
Explains the linearization function, including modes (1 Quadrant, 4 Quadrant) and coordinate setting.
Provides physical dimensions of the unit from front, side, and top views, including cut-out dimensions.
Lists detailed technical specifications for connections, power supply, inputs, outputs, accuracy, and environmental conditions.