7.3 Parameters
To
program each Presets, Click and go to
Parameter menu require password to log in
the initial factory setting is “ 0 “ for password
The password can be changed once log in.
There are approx.. 500 address for each
parameters. Parameters are grouped for
each settings as below
On the log in window, there are tool information about controller firmware version, LCD UI
graphic version and option card firmware version, screwdriver model, serial no
Parameter group
Group Parameter Address
1. Fastening Preset #1 to #15 A001 – A225
2. I/O
Input A226 – A233
Output A234 – A241
3. Screw count Number & cycle start A242 – A247
4. Crow foot option A265 – A269
5. Controller A270 – A306
6. Network IP address A307 – 320
7. Multi sequence Multi-A, Multi-B A321 – 340
8. Error 8 error history A341 – 348
Controller model A349
9. Model Model #1 to 15 A350 – 649
10. Advanced Function Advanced #1 to #15 A650 – 874
11. Firmware version A875
Please refer to the operation manual of ParaMon PC software for details of parameter settings.