— 4 — — 5 — — 6 —
5. Software Installation Information
To install NPort Administration Suite, insert the NPort Document &
Software CD into your computer’s CD-ROM drive. Once the NPort
Installation CD window opens, click on the INSTALL UTILITY button,
and then follow the instructions on the screen.
To view detailed information about NPort Administration Suite, click on
the DOCUMENTS button, and then select “NPort 5600 Series User’s
Manual” to open the pdf version of this user’s guide.
6. Pin Assignments and Cable Wiring
Serial Port RS-232 Pinouts (RJ45)
1
8
Pin
1
2
3
4
5
6
7
8
Signal
DSR (in)
RTS (out)
GND
TxD (out)
RxD (in)
DCD (in)
CTS (in)
DTR (out)
Serial Port RS-422/4-wire RS-485 Pinouts (RJ45)
1 8
Pin
1
2
3
4
5
6
7
8
Signal
RxD-
RxD+
GND
---
---
---
TxD+
TxD-
Serial Port 2-wire RS-485 Pinouts (RJ45)
1 8
Pin
1
2
3
4
5
6
7
8
Signal
Data-
Data+
GND
---
---
---
---
---
Serial Cables
RJ45 (8-pin) to Female DB9, for NPort 5610
NPort 5610
8 pins 9 pins
DSR
RTS
GND
TxD
RxD
DCD
CTS
DTR
RS-232
Device
DTR
CTS
GND
RxD
TxD
DCD
RTS
DSR
Cable Wiring
1
2
3
4
5
6
7
8
4
8
5
2
3
1
7
6
RJ45 Connector DB9 FemaleRJ45 Port DB9 Mal
RJ45 (8-pin) to Male DB9, for NPort 5610
NPort 5610
8 pins 9 pins
DSR
RTS
GND
TxD
RxD
DCD
CTS
DTR
RS-232
Device
DTR
CTS
GND
RxD
TxD
DCD
RTS
DSR
Cable Wiring
1
2
3
4
5
6
7
8
6
7
5
3
2
1
8
4
RJ45 Connector DB9 MaleRJ45 Port DB9 Female
RJ45 (8-pin) to Female DB25, for NPort 5610
NPort 5610
8 pins 25 pins
DSR
RTS
GND
TxD
RxD
DCD
CTS
DTR
RS-232
Device
DTR
CTS
GND
RxD
TxD
DCD
RTS
DSR
Cable Wiring
1
2
3
4
5
6
7
8
20
5
7
3
2
8
4
6
RJ45 Connector DB25 Female
RJ45 Port DB25
Male
RJ45 (8-pin) to Male DB25, for NPort 5610
NPort 5610
8 pins 25 pins
DSR
RTS
GND
TxD
RxD
DCD
CTS
DTR
RS-232
Device
DTR
CTS
GND
RxD
TxD
DCD
RTS
DSR
Cable Wiring
1
2
3
4
5
6
7
8
6
4
7
2
3
8
5
20
RJ45 Connector DB25 Male
RJ45 Port DB25
Female
7. Environmental Specifications
Power requirements
Power Input
Power Consumption
NPort 5610-8/16
NPort 5610-8/16-48V
NPort 5630-8/16
100 to 240 VAC, 47 to 63 Hz,
±48 VDC (38 to 72 VDC, -38 to -72 VDC)
200 mA for 100V, 145 mA for 240V
250 mA (at 48V max.)
212 mA for 100V, 130 mA for 240V
Operating temp. 0 to 55°C (32 to 131°F)
Operating humidity 5 to 95% RH
Dimensions (W×D×H)
198 × 45 × 480 mm (including ears)
198 × 45 × 440 mm (without ears)
Serial line protection 15 KV ESD for all signals
Magnetic isolation 1.5 KV for Ethernet
Power line protection
4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
Regulatory approvals FCC Class A, CE Class A, UL, CUL, TÜV
Copyright 2004
Moxa Technologies Co., Ltd.
All rights reserved.
Reproduction without permission is prohibited.
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
www.moxa.com
support@moxa.com.tw