Do you have a question about the MSK SL 05-25 W / L and is the answer not in the manual?
The operating manual consists of 4 parts. Prepared for supervisors and operators.
Chapter contains relevant standards and guidelines for MSK SLX Touch.
Provides contact details for Producer and Sales for any questions.
Identifies the MSK SLX with type plates showing producer, serial number, etc.
Explains how technical facts are presented using hyphens, dots, and position numbers.
Explains how dangers and information are presented using symbols like risk of death, injury, system damage, and notes.
Lists safety instructions to be observed during installation, operation, cleaning, and maintenance.
Details risks of death, injury, and system damage due to heat, cold, electrical voltage, etc.
Covers mains connection, drive means, emergency stop device, and motors.
States the MSK SLX is intended for snow production from drinking water.
Describes the process of snow creation using an internally cooled roller in a water bath.
Divides the MSK SLX into three areas (Food Sector, Spray Area, Non Food Sector) for hygiene.
Lists materials used in the food industry, their properties, and food-compatibility.
Details the components included in the MSK SLX delivery, specifying standard and optional items.
Guidance on lifting and moving the MSK SLX using forklift trucks or cranes.
General installation notes, including checking delivery, setup on a level base, and clearances.
Specifies recommended ambient and water temperatures for optimal operation.
Steps for initial setup, including electrical connection, visual inspection, and water hose installation.
Reiteration of optimal ambient and water temperatures and their impact on operation.
Procedure for testing the MSK SLX after initial setup to ensure proper functioning.
Instructions for decommissioning the MSK SLX for short or longer periods, including draining.
Step-by-step guide on how to start the MSK SLX, including pre-checks and water supply.
Procedure for safely shutting down the MSK SLX, including defrosting and draining.
Daily checks recommended to ensure proper functioning and prevent water damage.
Instructions for manually draining residual water when the unit is taken out of operation.
Manual drainage of residual water by unscrewing a fitting under the evaporator.
How to clean stainless steel and plastic parts of the housing using compatible cleaners.
Guidance on when and how to renew water hoses for inlet and outlet, and clean the water bath.
Instructions for checking the water bath for leaks and cleaning it from foreign substances.
Monthly checks for contamination or calcification on ice slide/guides and ice scraper adjustment.
Checks for solenoid valves related to drainage and water inlet by service technicians.
Annual checks and potential repair/renewal of rotary entry and flange bearings.
Lubricant change intervals for gear motors based on operating hours or years, or extreme conditions.
Annual functional check of the entire electrical system and supply line.
Annual functional check of the limit switch on the switching flap.
Annual check by a refrigeration specialist, with monthly checks on sight glass for passage and color.
Check function of the expansion valve during maintenance and replace if necessary.
Troubleshooting guide for compressor not running, covering switch, fuse, pressure switch, and power supply.
Troubleshooting guide for heating failure, covering switch, fuse, power supply, and defective heating.
Troubleshooting guide for water leaks from the drain, covering ball valves and drain valve.
Troubleshooting for unit switching off completely, primarily due to a tripped fuse.
Troubleshooting for poor snow output, considering ambient/water temps, lime, conductivity, and pressure.
Explanation of how MSK SLX visualizes status via piezo button or text messages on the PLC.
Indicates system is off when no light rings are on.
Indicates system is in operation when the blue LED ring lights up continuously.
Indicates system is in standby mode when the red LED ring lights up continuously.
Blue LED flashes every 1s ON, 2s OFF, indicating compressor pendulum protection.
Blue LED flashes every 2s ON, 10s OFF, indicating residual water in the machine.
Red LED flashes every 1s ON, 1s OFF, indicating sensor mode 1 triggered.
Blue and red LEDs flash every 1s ON, 1s OFF, indicating an HD disorder.
Blue and red LEDs flash in 1 to 2 cycles, indicating an ND disorder.
Blue and red LEDs flash in 1 to 3 cycles, indicating snow congestion.
Blue and red LEDs flash in 2 to 1 cycles, indicating a Hall sensor gear motor issue.
Blue and red LEDs flash in 2 to 2 cycles, indicating motor protection for the drive motor.
Blue and red LEDs flash in 3 to 1 cycles, indicating a water inlet fault.
Blue and red LEDs flash in 3 to 3 cycles, indicating optional sewage pump flooded.
Blue and red LEDs flash in 4 to 1 cycles, indicating optional rotating field monitoring.
Blue and red LEDs flash in 5 to 1 cycles, indicating optional level sensor triggered.
| Brand | MSK |
|---|---|
| Model | SL 05-25 W / L |
| Category | Snow Blower |
| Language | English |