EN
12
Rev. 27.02.2017
After activation the motor
is too loud. It is not possi-
ble to suspend a load.
Current and voltage
too low
The capacitor is
damaged.
Supply correct cur-
rent and voltage
Replace the capacitor
Unusually loud noises Incorrect lubrication
Transmission and
bearing damaged due
to wear and tear
Incorrectly mounted
Apply more grease
Check and replace
transmission and
bearing if needed
Check assembly and
repair element ma-
king the noise
Incorrect power supply
to hoist
No earthing
Internal cabling in
contact with the
housing
Check or connect
earth
Check internal cabling
The traverse mechanism
does not work
The traverse button
is faulty
Repair or adjust the
traverse button
The motor is unable to lift
the load
Continuous operati-
on leads to excessive
build up of heat in the
internal motor coils
and may even lead to
it burning out
Cool the motor and
then start it up as per
normal
INSTRUKCJA OBSŁUGI
PROCAT 500
PROCAT 300
PROCAT 1200
PROCAT 800
MSW MOTOR TECHNICS