Safety info for modifications to UL listed products.
Instructions for starting and stopping the unit.
Procedure to display and reset unit alarms.
Essential safety measures for operating the unit.
Safety guidelines for maintenance activities.
Important safety measures regarding refrigerant, welding, parts, and unit access.
Guidance on selecting an appropriate installation location.
Detailed instructions for making hydraulic connections.
Instructions for connecting the unit to the main power supply.
Step-by-step instructions for safely starting the unit.
Explanation of controller button functions.
How to display and change the unit's setpoint.
General information on alarms managed by the controller.
Procedure to display and reset alarms using the ALrM function.
List and description of general alarms.
Information on probe fault alarms, causes, and resets.
Details on high pressure or compressor thermal alarms.
Information on low pressure switch alarms.
Details on high pressure alarms.
Details on low pressure alarms.
Information on anti-freeze alarms and reset.
Anti-freeze alarms specific to chiller mode.
Information on level sensor or flow meter alarms.
Details on compressor thermal alarms.
Details on fan thermal alarms.
Information on high condensing pressure unloading indications.
Details on high condensing pressure recovery disabling indications.
Information on evaporator inlet high water temperature unloading.
Details on evaporator water pump thermal alarms.
Information on phase monitor alarms.
Information on unit configuration alarms.
How to diagnose alarms switching from automatic to manual reset.
Procedure to display and delete the alarms log.
Overview of parameter programming levels and access.
Step-by-step guide to accessing parameter menus.
Detailed steps for modifying parameter values.
How to use the hot-key for programming and data transfer.
Methods for starting and stopping the unit.
How to view alarm statuses and perform resets.
Procedure for programming parameters via keypad.
Procedure for visualizing and resetting alarms.
List of programmable parameters and their settings.
Detailed descriptions of thermoregulation parameters.
General guidance on unit maintenance.
Schedule of recommended maintenance operations and frequencies.
Troubleshooting steps for high tank water outlet temperature.
Troubleshooting steps for insufficient water pressure at the pump outlet.
Troubleshooting steps for level sensor or flow meter alarms.
Troubleshooting steps for high pressure switch trips.
Troubleshooting steps for compressor protection trips.
Troubleshooting steps for a blank display and no LEDs.
Troubleshooting steps for probe damage alarms.
Troubleshooting steps for low water temperature or flow alarms.
Troubleshooting steps for pump thermal cutout alarms.
Troubleshooting steps for unit configuration errors.
Troubleshooting steps for processor/EEPROM data saving issues.