Meter’s Specifications
Clamp size : opening 1.2" (30mm) approx.
Diode test : test current of 0.3mA typical ; open circuit voltage
1.5V DC typical
Continuity check: treshold <150Ω; test current <0.5mA
Low battery indication:
+
is displayed
Over range indication: "OL" is displayed
Measurement rate: 2 per second, nominal
Input impedance : 10MΩ (VDC and VAC)
Display : 4000 counts LCD
AC current : 50-60Hz (AAC)
AC Voltage bandwidth : 50-400Hz (VAC)
Operating temperature: 41 to 104ºF (5 to 40ºC)
Storage temperature : -4 to 140ºF (-20 to 60ºC)
Operating humidity : max of 80%, up to 87ºF (31ºC) decreasing linearly to
50% at 104ºF (40ºC)
Storage humidity : <80%
Operating altitude : 7000 feet (2000 meters) maximum
Overvoltage : category III 600V
Battery : two "AAA" 1.5V batteries
Auto OFF: after approx. 30 minutes
Dimensions/weight : 200x66x37mm / 205g
Accessories: test leads, carrying case, alligator clips, temperature probe, 2
ʺAAAʺ 1.5V batteries, instruction manual
Safety : For indoor use and in accordance with Overvoltage
Category II, Pollution Degree 2. Category II includes local
level, appliances, portable equipment, etc., with transient
overvoltage less than overvoltage Cat. III