Accuracy: AC 50/60Hz (23℃③5℃, less than 80% RH)
Range
Mini. Resolution
Accuracy
AC 20A
0.01A
③1.2%rdg ③5dgt
AC 200A
0.1A
23mmφ
Blanking of all digits except MSD1
1999 count
"B" mark on LCD readout
"D・H" mark on LCD readout
2 times/sec.
Less than AC 600V
Withstanding voltage
AC3700V/1 minute between CT core and outer case
10MΩ or more between internal circuit and CT core.
0℃ to +40℃, <80%RH (non-condensing)
-10℃ to +60℃, <70% RH (non-condensing)
LR-44(1.5V)x2 or SR-44x2
Approx. 2.5mW
Approx. 100 hours (LR-44)
Approx. 200 hours (SR-44)
48(W)x146(H)x20(D)mm
Approx. 80g
Batteries (LR-44)…….…….2
Instruction manual……..…1
Soft case……………….…….1
3. CAUTION
● Before operating this instrument, familiarize yourself with all instructions
outlined in this manual.
● Always check to make sure that the function switch is set to the proper position.
● When making measurements, use CAUTION as dangerous voltages may be
present in normally safe areas.
● To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC
rms. Such voltages pose a shock hazard.
● Never make measurements with the battery cover OFF.
● Never fail to keep the maximum tolerable input.
● Never operate this instrument if it becomes wet, damp or has any liquid
condensation build-up on any part of the instrument.
● Never make measurements for uninsulated conductors or bus bars.