Procedures for lifting and inspecting the unit upon arrival.
Instructions for placing the unit outdoors on a level curb.
Steps for attaching air intake and condenser coil hoods.
Guidelines for connecting the supply air ductwork according to standards.
Instructions for installing a vented P-trap for the condensate drain.
Details on electrical service entrance, wiring, voltage, and grounding.
Information on connecting the Novar or Danfoss controller and its inputs.
Checks for correct compressor rotation and temperature stabilization.
Overview of the Novar IOM controller and microprocessor functions.
Steps to initiate unit operation via external FAN contacts.
Controller logic for cooling, dehumidification, and heating stages.
Navigating the microprocessor interface, menus, and status screens for operation.
Procedure for safely turning off the unit by de-energizing output 1.
Method for adjusting supply airflow by moving the fan relative to the inlet cone.
How VFDs control fan speeds to maintain discharge pressure.
Routine checks of supply air fan and temperature stabilization.
Recommended maintenance tasks listed with their frequency.
Checking supply air outlet duct for leaks or blockages.
Procedure for replacing disposable air filters in the unit.
Checking seal clearance and wear against the HoneyCombe® wheel.
Procedures for inspecting supply, reactivation, and condenser fans.
Checking the drive motor and belt for wear or cracking.
Inspecting rollers supporting the HoneyCombe® wheel for wear.
Checking disconnect, wires, relays, VFDs, and microprocessor.
Inspecting the drip tray and drain line for blockages or water issues.
Step-by-step guide for removing and replacing the wheel, belt, or seals.
Checking the desiccant wheel for damage, alignment, and plugging.
Procedures for cleaning the desiccant wheel using vacuum and compressed air.
Details on the one-year warranty for workmanship and materials.
Explanation of how the HCU removes moisture using the HoneyCombe® wheel.
General approach to troubleshooting, checking alarms, VFDs, and microprocessor.
Details on fault detection, displays, and processing for Inverter errors.
Guidance on troubleshooting Inverter and motor operational issues.
Procedures for daily and periodic inspection of the Inverter.
Overview of duct furnaces for heating/cooling/dehumidification systems.
Venting, clearances, and plumbing requirements for installation.
Procedures for starting up, shutting down, and operating the appliance.
Periodic cleaning of vents, pipes, burners, and inspection of components.
Parameter settings for initialization, operation mode, frequency reference, and rotation.
Parameters for stop selection, local frequency, V/f settings, and output frequency limits.
Parameters for acceleration/deceleration times and frequency references.
Parameters for motor current, protection, and cooling fan operation.
Parameters for multi-function I/O, analog references, carrier frequency, and jump functions.
Parameters for DC control, stall prevention, overtorque detection, and timing.
Parameters for command memory, compensation, reference use, and error logs.
Error log and software number parameters.