Do you have a question about the Munters FA6 and is the answer not in the manual?
Airflow | 600 m³/h |
---|---|
Humidification capacity | 6 kg/h |
Frequency | 50 Hz |
Water consumption | 6 l/h |
Weight | 50 kg |
Water Connection | 1/2" |
The FA6 unit is designed for easy installation into existing or new HVAC systems, requiring standard electrical and water connections.
Guidance on selecting the appropriate location for the FA6 unit within the AHU, ensuring structural support and access.
Details for connecting the circulating water system, including pressure and filter recommendations.
Information for connecting the direct water system, specifying pressure and filter requirements.
Specifies the minimum and maximum water pressure required at the connection point for optimal operation.
Recommends pre-filter classes (EU3 and EU7) to protect the humidifier from dust.
Instructions for connecting the discharge pipe to a wastewater system, including water trap considerations.
Guidance on calculating the correct size for the water trap based on operating pressure.
Specific instructions for mounting pressure reduction hoses related to the fan and humidifier.
Details on required connection points and minimum space needed for service and inspection.
Table detailing pump sizes, voltage, frequency, power, and rated current for the circulation pump.
Sound level data in decibels across different octave bands for various FA6 models.
Specifies the maximum allowable operating temperatures for air, water, and internal components.
Lists the Ingress Protection (IP) ratings for the pump, solenoid valve, and drain valve.
Wiring diagrams for connecting the pump motor for 230V and 400V power supplies.
Wiring instructions for solenoid valves, including 230/24 VAC connections for step control.
Diagram showing the electrical connections for the motorized drain valve.
Highlights the responsibilities of personnel working with or operating the humidifier.
Warns about the risks of personal injury or product damage due to incorrect usage.
Provides guidance on the proper disposal methods for used humidifier cassettes.
Instructions for inspecting, storing, and protecting the humidifier upon delivery.
Steps for checking the humidifier for damage after unpacking and before installation.
Guidelines for safely handling and lifting the humidifier unit to prevent damage.
Steps for installing the FA6 unit when it is delivered in a fully assembled state.
Instructions for assembling the FA6 unit when it is delivered in separate components.
Detailed steps for assembling the drain system for the FA6 humidifier unit.
Checks to perform before the initial startup of the FA6 humidifier.
Procedure for the initial startup, including rinsing the humidifier to remove manufacturing residues.
Guide on how to adjust the bleed-off flow rate for optimal humidifier performance.
Instructions for cleaning the distribution holes in the header for even water distribution.
Recommended periodic maintenance tasks for the FA6 unit, typically performed annually.
Detailed list of service routines to be performed during the annual maintenance of the FA6.
Items to inspect annually, including water level, bleed-off valve, and cassette condition.
Procedure for cleaning the water reservoir and the pump filter to ensure proper operation.
Instructions on how to carefully remove humidifier cassettes and droplet separators.
Procedures to follow when restarting the FA6 unit after maintenance or servicing.
A table listing common faults, possible causes, and remedial measures for the FA6 humidifier.
Information on how to order replacement parts, including necessary details to provide.
An illustrated list identifying the various components of the FA6 unit.