EasyManua.ls Logo

Mustang 24 - Page 4

Mustang 24
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 2
-
1. Specifications
Horizontal design, R410A, Heating & Cooling
Model MUSTANG 24 MUSTANG 30
* Heating Capacity at Air 28, Water 28,Humidity 80%
Max Heating Capacity kW 24 30
Rated Heating Capacity kW 21.5 25.5
Input Power (Heating) kW 3.31 4.47
MAX C.O.P 6.5 6.7
C.O.P 5.7 5.7
* General data
Compressor type Scroll / R410A Scroll / R410A
Voltage 380-415V~50Hz/3PH 380-415V~50Hz/3PH
Running Current Heating A 6.7 8
Advised pool volume
(with pool cover)
75-120 90-130
Advised water flux m
3
/h 6.2~12 7.1~14
Water Pressure Drop KPa 16 18
Heat exchanger Titanium in PVC
Water connection mm 50
No. of Fan 1
Ventilation type Horizontal
Fan Speed RPM 650
Noise level(10m) dB(A) 47 48
Noise level(1m) dB(A) 57 58
Net Weight kg 91 113
Net Dimension (WxDxH) mm 1072*420*830 1072*420*830
Packing Dimension (WxDxH) mm 1155*471*885 1155*471*885