DOC: OM-MYLIFE-19 My Life Hot Tubs
2019 Owner’s Manual
TROUBLESHOOTING YOUR SPA
COMMON PROBLEMS AND HOW TO SOLVE THEM
NOTICE:
A large number of problems on start-up can be attributed to mis-wiring and
a poor understanding of how the spa operates and its' features. Take the
time to read and understand this manual. If you have any questions contact your dealer.
Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD)
Shuts Off On Initial Start-Up
Probable cause:
Mis-wiring of GFCI/RCD.
Action:
Contact electrician and/or dealer.
Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD)
Shuts Off (Not on Initial Start-Up)
Probable cause:
One or more pieces of equipment is shorting to ground or total current draw exceeds
GFCI/RCD rating.
Action:
Contact dealer: DO NOT use spa. Take measures to ensure others do not use spa.
Spa is CompletelyDead(No Circulation and No Display on Topside Control Panel)
Probable cause #1:
GFCI/RCD has tripped (shut off).
Action:
Reset GFCI/RCD and monitor for futures trips. Alert dealer if problem persists.
Probable cause #2:
Breaker or fuse before GFCI/RCD is tripped or blown.
Action:
Shut off GFCI/RCD, reset breaker or replace fuse, reset GFCI/RCD and test. Contact
electrician or dealer if problem persists.
Probable cause #3:
Transformer fuse blown in spa pack.
Action:
Locate fuse in spa pack, test and/or replace. Or contact dealer for service.
Probable cause #4:
Insufficient line voltage to power up spa pack processor.
Action:
Contact electrician to measure line voltages and inspect supply connections.