700015770/10105109-ar-en-he-hi-zh/V03 Ausgabe 2019-11
Manufacturer
Ypsomed AG
Brunnmattstrasse 6
3401 Burgdorf
Switzerland
ar
en
Manufacturer
ru
hi
he
ar
en
Non-pyrogenic
ru
hi
he
ar
en
Date of manufacture
ru
hi
he
ar
en
Keep away from sunlight
ru
hi
he
ar
en
Use-by date
ru
hi
he
ar
en
Keep dry
ru
hi
he
ar
en
Catalogue number
ru
hi
he
ar
en
Unique Device Identifier
ru
hi
he
ar
en
Medical Device
ru
hi
he
ar
en
Single sterile barrier system.
Sterilized using ethylene oxide.
ru
hi
he
ar
en
Consult instructions for use
ru
hi
he
zh
失效日期
ar
en
Caution
ru
hi
he
ar
en
Batch code
ru
hi
he
ar
en
Do not use if package is damaged
ru
hi
he
ar
en
Do not re-use
ru
hi
he
ar
®
mylife
™
®
mylife
™
U100
®
mylife
™
®
mylife
™
®
mylife
™
®
®
mylife
™
1
2
3
4
5
6
7
8
9
10
11
mylife
™
12
®
mylife
™
®
3082
mylife
™
®
7
®
®
®
®
®
Instructions for use
Headquarters Ypsomed AG // Brunnmattstrasse 6 // 3401 Burgdorf // Switzerland //
info@ypsomed.com // www.mylife-diabetescare.com // +41 34 424 41 11
Australia Ypsomed Australia PTY Limited // 602/20 Bungan St // Mona Vale NSW 2103 //
info@mylife-diabetescare.com.au // www.mylife-diabetescare.com.au // Customer Care Free Call: 1800 447 042
India Ypsomed India Private Ltd. // 10/61/1-F, Kirti Nagar Industrial Area // New Delhi-110015 //
info@ypsomed.co.in // www.mylife-diabetescare.co.in // Customer Care: 099999 75157
Israel Tritech Biomed Ltd. // 22 Ha-Nagar Street // Industrial Zone Newe Ne’eman B // Hod Hasharon 4501317 //
info@tritechbiomed.co.il // Customer Care: 1-800-35-35-66
450131722
450131722
en
Sterile device
The mylife
™
YpsoPump
®
Reservoir is sterile provided that the packaging has
neither been opened nor damaged. If the packaging shows signs of damage,
then use a different reservoir.
Intended use
The mylife
™
YpsoPump
®
Reservoir is intended to be lled with a rapid-acting
insulin at a concentration of 100 U/ml and used with the mylife
™
YpsoPump
®
insulin pump.
Warnings
Prevent risk of incorrect medication:
Ensure the use of the correct drug liquid and check the label of the
vial before lling the reservoir.
Remove air bubbles from the reservoir prior to its insertion into the
mylife
™
YpsoPump
®
.
Prevent risk of infection:
Never pull the stopper beyond the 1.6-ml mark.
Do not re-use the transfer adapter or the reservoir.
Safety measures
Check the reservoir for cracks and damages and do not use the reservoir after
the expiration date on the packaging. Follow the user manuals for mylife
™
YpsoPump
®
and mylife
™
YpsoPump
®
Orbit
®
infusion sets and the explanations
of the symbols on the packaging. The reservoir is solely intended for single use.
You will need the following:
a) Insulin vial
b) Alcohol swabs
c) Reservoir with plunger rod
d) Transfer adapter
1 Wash your hands thoroughly with soap and water.
2 Clean the septum of the insulin vial with an alcohol swab.
3 Remove the reservoir and the transfer adapter from the packaging
(c and d) without touching the septum.
4 Attach the transfer adapter to the reservoir and advance the stopper all
the way forward.
5 Then pull the plunger rod backwards until the entire reservoir is lled
with air.
6 Attach the other end of the transfer adapter to the insulin vial.
7 Inject all of the air into the insulin vial. This will make it easier to then
withdraw insulin from the vial.
8 Turn the reservoir, including the insulin vial, upside down. Very gently
draw the insulin into the reservoir.
9 Check the reservoir for air bubbles. If air bubbles are in the reservoir,
carefully tap the side of the reservoir. Then press the plunger rod to
push the air bubbles out of the reservoir. Repeat if necessary.
10 Remove the transfer adapter from the vial. Dispose of the transfer
adapter in accordance with local laws.
11 Twist off the plunger rod and dispose of it.
12 Follow the instructions in the user guide for the mylife
™
YpsoPump
®
in order to insert the reservoir into the mylife
™
YpsoPump
®
.
Storage
You can ll the reservoir with a rapid acting insulin analogue as described
by your doctor/physician and store it in the fridge (2 – 8 °C) for up to
30 days. The lled reservoir can be used in the mylife
™
YpsoPump
®
for up
to 7 days.
For more information regarding your insulin, please consult the
package leaet issued by the insulin manufacturer. The storage time and
storage conditions may differ.
Compatible with: Fiasp
®
, NovoRapid
®
, Humalog
®
, Apidra
®
,
Insulin lispro Sanofi
®