Assembly- and Operation Manual, 170504 8
Technical Data
DC
AC
DC-voltage
100 - 360 V (max.)
Heating power
see nameplate
MPP-range
150 - 360 V
Power
connection
Single phase, grounded
plug, 230 V, 50-60 Hz
Number of MPP
trackers
1
Recommended
fuse
10 16 A
Max. input current
10 A, internally limited
Power cord
3 m
Nominal power
2,000 W at 25°C ambient
temperature, derating at
overheat
Standby-power
consumption
0 W at DC operation, <2 W at
AC operation
DC inputs
Original MC4, 1 string
PV panel
configuration
4 - 8 pcs 60 cells
polycrystalline
MPP- efficiency
99,8 %
General Data
Operating pressure
max. 10 bar (1MPa)
Overall efficiency
>99% at nominal power
Protection class
IP20
Operating
temperature range
5 °C to 40 °C
Operating display
3 LED’s
Interface
Serial IR Interface
Dimensions
(WxHxD)
130 x 180 x 600 mm incl.
heating rod
Heating rod length
45 cm
Heating rod thread
1 ½ inch
Weight
2 kg with power cord,
without carton
Subject to change.
my-PV GmbH
Teichstrasse 43, 4523 Neuzeug
www.my-pv.com

Other manuals for MYPV ELWA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MYPV ELWA and is the answer not in the manual?

MYPV ELWA Specifications

General IconGeneral
CategoryWater Heater
ManufacturerMYPV
ModelELWA
Voltage230 V
Frequency50 Hz
Protection ClassIP21
MountingWall-mounted
ControlElectronic
Power Consumption0-3 kW
ThermostatYes
ProtectionOverheat protection
CertificationCE
Power Output0-3000 W
MaterialStainless steel