2. SETUP
FUSE REPLACEMENT
MultiFlash, MultiFlash Q+, MultiFlash LR Q+, both MultiFlash Q+ Rayzr, and MultiFlash M3 use a 12A 250V
slow-blow fuse (5x20mm). To replace fuse:
1. With a screwdriver turn the fuse cap counter-clockwise to remove fuse cap with fuse.
2. Replace fuse attached to fuse cap.
3. Reinsert fuse cap with new fuse and tighten clockwise.
FIXTURE LINKING
A DMX data link is needed to operate one or more fixtures via a DMX-512 lighting console. The combined
number of channels required by all the fixtures on a DMX data link determines the number of fixtures the
DMX data link can support.
Important: Fixtures on a DMX data link must be daisy -chained in one single line. To comply with the
EIA-485 standard, no more than 32 devices should be connected on one data link. Connecting more
than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in
deterioration of the digital DMX signal.
Maximum recommended DMX data link distance between fixtures: 984 ft. (300 meters).
POWER LINKING (MultiFlash M3, MultiFlash Rayzr)
The MultiFlash Jr and MultiFlash Rayzr has Neutrik® PowerCon IN and THRU connections allowing power
linking (daisy-chaining). Depending on the power provided, you should not exceed the power threshold.
Max. 5 units 100-120V; max. 10 units 208-240V for MultiFlash Jr.
Max. 5 units 100-120V; max. 10 units 208-240V for MultiFlash Q+ Rayzr 50cm.
Max. 3 units 100-120V; max. 6 units 208-240V for MultiFlash Q+ Rayzr 100cm.
4