8.2 Installation of the
CFDL Controller
8.2
Installation of the C
FDL Controller
8.2.1
Ambient
condition
The condition of
CFDL controller is same as CFD
controller.
Please refer to
2.2.1 Ambient condition.
8.2.2
Installation
procedure
and
place
(1) Make sure to install the intake
and exhaust port 200mm or more away from the
wall.
(2) Install the controller so that the height of power switch from work floor will be 0.6m to 1.9m.
(3) CFDL controller is not dust-proof or drip-proof structured.
In case of using it under the dust or mist environment then, please add the following option Controller
protection box. In case of using the protection box, the condition of the ambient temperature is 0 to 30
For
CFDL1
/
CFDL2
CFD-OP133-A
(Supports
protection
level
IP54)
For
CFDL4
CFDL-OP133-A
(Supports
protection
level
IP54)