EasyManua.ls Logo

Napa BK 700-2606 - User Manual

Napa BK 700-2606
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
u
n
7
8
5
6
3
4
A
AC
mV
kM
DC
¡ã
¡ã
F
C
Hz%
9
2
1
A
400A
40A
DC CLAMP METER (1000A)
MODEL BK 700-2606
USER INSTRUCTIONS
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer
to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present
Double insulation
SAFETY NOTES
Do not exceed the maximum allowable input range of any function
Do not apply voltage to meter when resistance function is selected.
Set the function switch OFF when the meter is not in use.
WARNINGS
Set function switch to the appropriate position before measuring.
When measuring volts do not switch to current/resistance modes.
Do not measure current on a circuit whose voltage exceeds 240V.
When changing ranges using the selector switch always disconnect the test leads from
the circuit under test.
Do not exceed the maximum rated input limits.
CAUTION !!
Improper use of this meter can cause damage, shock, injury or death. Read and
understand this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before
operating the meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than
25VAC rms or 35VDC. These voltages are considered a shock hazard.
Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should
be used to ensure that the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
INPUT LIMITS
Function
Maximum Input
A AC
1000A
V DC, V AC
600V DC/AC
Resistance, Diode, Continuity, Capacitance,
Frequency, Duty Cycle, Test
250V DC/AC
Temperature (/)
60V DC/24V AC
METER DESCRIPTION
1. Current clamp
2. Clamp trigger
3. Data Hold and Backlight button
4. Mode select button
5. Hz/% button
6. LCD display
7. COM input jack
8. Rotary Function switch
9. ZERO button
10. Range select button
11. V Ω℃/ jack
** Battery compartment on rear
DISPLAY
1. AC / DC AC (Alternating Current) and DC (Direct Currrent)
2. (to left of reading) Minus sign (if applicable)
3. 8.8.8.8 4000 count (0 to 3999) measurement reading
4. AUTO AutoRange mode
5. Diode test mode
6. ))) Audible Continuity
7. HOLD Data Hold mode
8. ,, ,m,V,A,K,M,Ω, Units of measure list
Question and Answer IconNeed help?

Do you have a question about the Napa BK 700-2606 and is the answer not in the manual?

Overview

The NAPA PROFESSIONAL DIAGNOSTICS DC Clamp Meter (1000A), Model BK 700-2606, is a versatile handheld device designed for electrical measurements. It features a current clamp for non-contact current measurements and test lead inputs for various other electrical parameters.

Function Description:

The meter is capable of measuring a wide range of electrical parameters:

  • AC Current (A AC): Up to 1000A.
  • DC Voltage (V DC): Up to 600V.
  • AC Voltage (V AC): Up to 600V.
  • Resistance (Ω): Up to 40.00MΩ.
  • Diode Test: For checking diode functionality.
  • Continuity: With an audible indicator for resistance below 100Ω.
  • Capacitance (F): Up to 100.0µF.
  • Frequency (Hz): Up to 100.0kHz.
  • Duty Cycle (%): From 0.5 to 99.0%.
  • Temperature (°C/°F): From -20 to 1000°C (-4 to 1832°F) using a Type-K thermocouple (probe accuracy not included).

Important Technical Specifications:

  • Input Limits:
    • A AC: 1000A
    • V DC, V AC: 600V DC/AC
    • Resistance, Diode, Continuity, Capacitance, Frequency, Duty Cycle, Test: 250V DC/AC
    • Temperature (°C/°F): 60V DC/24V AC
  • Measurements Rate: 2 per second, nominal.
  • Input Impedance: 7.8MΩ (VDC and VAC).
  • Display: 4000 counts LCD.
  • AC Current Bandwidth: 50/60Hz.
  • AC Voltage Bandwidth: 50/60Hz.
  • Operating Temperature: 14 to 122°F (-10 to 50°C).
  • Storage Temperature: -14 to 140°F (-30 to 60°C).
  • Relative Humidity: 90% (0°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C).
  • Altitude: Operating: 3000m; Storage 10,000m.
  • Overvoltage Category: Category III 600V.
  • Battery: One "9V" Battery.
  • Auto Off: Approximately 35 minutes.
  • Dimensions/Weight: 229 x 80 x 49mm/303g.
  • Safety: Designed for indoor use and in accordance with Overvoltage Category II, Pollution Degree 2.

Accuracy (Typical):

  • DC Current:
    • 40.00 AAC: ± (2.8% + 10 digits)
    • 400.0 AAC: ± (2.8% + 5 digits)
    • 1000 AAC: ± (3.0% + 5 digits)
  • AC Current:
    • 40.00 AAC: ± (3.0% + 10 digits)
    • 400.0 AAC: ± (3.0% + 5 digits)
    • 1000 AAC: ± (3.0% + 5 digits)
  • DC Voltage:
    • 400.0 mVDC: ± (0.8% + 3 digits)
    • 4.000 VDC, 40.00 VDC, 400.0 VDC: ± (1.5% + 3 digits)
    • 600 VDC: ± (2.0% + 3 digits)
  • AC Voltage:
    • 400.0 mVAC: ± (0.8% + 20 digits)
    • 4.000 VAC, 40.00 VAC: ± (1.8% + 5 digits)
    • 400.0 VAC, 600 VAC: ± (2.5% + 5 digits)
  • Resistance:
    • 400.0 Ω: ± (1.0% + 4 digits)
    • 4.000K Ω, 40.00K Ω, 400.0K Ω: ± (1.5% + 2 digits)
    • 4.000M Ω: ± (2.5% + 3 digits)
    • 40.00M Ω: ± (3.5% + 5 digits)
  • Capacitance:
    • 40.00nF: ± (5.0% reading + 100 digits)
    • 400.0nF, 4.000 µF, 40.00 µF: ± (3.0% reading + 5 digits)
    • 100.0 µF: ± (5.0% reading + 5 digits)
  • Frequency:
    • 5.000Hz: ± (1.5% reading + 5 digits)
    • 50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz: ± (1.2% reading + 2 digits)
  • Duty Cycle: ± (1.2% reading + 2 digits)
  • Temperature:
    • -20 to 1000 °C: ± (3.0% reading + 5°C)
    • -4 to 1832 °F: ± (3.0% reading + 7°F)

Usage Features:

  • Current Clamp: Allows for non-contact measurement of AC current by enclosing a single conductor wire. The clamp has an opening of approximately 30 mm (1.2").
  • Rotary Function Switch: Used to select the desired measurement function (A AC, V DC/AC, Resistance, Diode, Continuity, Capacitance, Frequency, Duty Cycle, Temperature).
  • MODE Button: Toggles between AC/DC for voltage and current, and selects specific sub-functions like resistance/diode/continuity or °C/°F for temperature.
  • Hz/% Button: Toggles between frequency and duty cycle measurements.
  • ZERO Button: Used for zeroing the display, particularly for current measurements to eliminate residual readings.
  • Range Select Button: Allows for manual ranging, overriding the default auto-ranging feature. Pressing and holding returns to auto-ranging. (Note: Manual ranging does not function in AC Current, Diode, and Continuity check functions).
  • Data Hold and Backlight Button:
    • A short press activates/deactivates the Data Hold feature, freezing the current reading on the LCD. The "HOLD" icon appears.
    • A long press (one second) activates/deactivates the backlight for improved visibility in low-light conditions.
  • Low Battery Indication: "BAT" is displayed when the battery is low.
  • Over-range Indication: "OL" is displayed when the measurement exceeds the selected range.
  • Safety Warnings: Emphasizes disconnecting test leads before current clamp measurements, discharging capacitors before capacitance/resistance/continuity tests, and observing input limits.

Maintenance Features:

  • Battery Replacement: The meter uses one 9V battery (NEDA1604, 6F22 006P). Replacement involves removing a Phillips head screw from the back, opening the battery compartment, replacing the battery, and re-assembling.
  • General Safety: Users are advised to inspect test leads and the meter for damage before use, remove the battery for long-term storage, and ensure the function switch is OFF when not in use.
  • Warranty: The product carries a One Year "Repair/Return" warranty (code 724) covering manufacturer defects, excluding dead batteries and blown fuses. Technical assistance and return authorization are available through a toll-free hotline.

Napa BK 700-2606 Specifications

General IconGeneral
BrandNapa
ModelBK 700-2606
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals