IOM
W415-1395 / C / 06.26.2017
Wolf Steel Ltd�, 24 Napoleon Rd�, Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone866-820-8686•Fax705-725-1150•www.napoleonheatingandcooling.com•
hvac@napoleonproducts.com
MANUFACTURERRESERVESTHERIGHTTODISCONTINUE,ORCHANGEATANYTIME,
SPECIFICATIONSORDESIGNSWITHOUTNOTICEANDWITHOUTINCURRINGOBLIGATIONS.
INSTALLATION AND OPERATING
INSTRUCTIONS
Powered By:
ConformstoULStandard1995.Certiedto
CAN/CSA Standard C22�2 No�236�
9700539
• 13,14&16SEERefciencies
• Capacitiesfrom1.5tonto5.0tons
• UtilizesenvironmentallyfriendlyR-410Arefrigerant
• HighEfciencyCopelandScrollCompressors
• Micro Channel Condenser
• SweptFanBlades
Congratulations on the purchase of your Napoleon Air Conditioner.
Napoleon’s line of Split Air Conditioners offer industry leading quality
and are equipped with multiple advanced features:
FEATURES:
13, 14 & 16 SEER SPLIT SYSTEM AIR CONDITIONERS
ELECTRICAL SHOCK, FIRE OR
EXPLOSION HAZARD
FAILURE TO FOLLOW SAFETY WARNINGS
AND INSTRUCTIONS EXACTLY COULD RE-
SULT IN SERIOUS INJURY, DEATH OR PROP-
ERTY DAMAGE.
WARNING
!!
THIS INFORMATION IS INTENDED FOR USE
BY QUALIFIED HVAC TECHNICIANS
POSSESSING ADEQUATE BACKGROUNDS
OF ELECTRICAL AND MECHANICAL
EXPERIENCE. ANY ATTEMPT TO REPAIR
A CENTRAL AIR CONDITIONING PRODUCT
MAY RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
THE MANUFACTURER OR SELLER CANNOT
BE RESPONSIBLE FOR THE
INTERPRETATION OF THIS INFORMATION,
NOR CAN IT ASSUME ANY LIABILITY IN
CONNECTION WITH ITS USE.
UNIT CONTAINS R-410A REFRIGERANT
AND POE COMPRESSOR OIL! USE ONLY
R-410A REFRIGERANT AND APPROVED POE
COMPRESSOR OIL.
REFRIGERANT LINES MUST BE BRAZED AND
RATED FOR R410 PRESSURES!
PROPER SERVICE EQUIPMENT IS
REQUIRED. USE ONLY R-410A APPROVED
SERVICE EQUIPMENT.
FAILURE TO USE PROPER SERVICE TOOLS
MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
INSTALLER: PLEASEFAMILIARIZEYOURSELFWITHTHISMANUALBEFORE
PROCEEDINGWITHTHEINSTALLATION.LEAVETHISMANUAL
WITHTHEAPPLIANCEFORFUTUREREFERENCE.
CONSUMER:RETAINTHISMANUALFORFUTUREREFERENCE.
INSPECT THE SHIPPING CONTAINER IMMEDIATELY UPON RECEIVING YOUR UNIT. ANY DAMAGE SHOULD BE NOTED ON
FREIGHT BILL BEFORE SIGNING AND CLAIMS SHOULD BE FILLED WITH CARRIER AS SOON AS POSSIBLE. MAKE SURE THAT
RATING PLATE MATCHES THE MODEL NUMBER YOU PURCHASED.

Questions and Answers

  • C
    Crystal WoodsAug 3, 2025
    How to troubleshoot Napoleon Air Conditioner unit that will not operate?
    • R
      Rebecca RiversAug 3, 2025
      If your Napoleon Air Conditioner unit isn't working, start by checking the voltage at the contactor to ensure the power connection isn't loose. Also, inspect the fuses and breaker, replacing or resetting them as necessary. You can also try to reset the unit. Check for 24VAC at the contactor coil, and replace the contactor if it's open. Examine the wiring and replace the transformer if it's defective. Finally, if provided, reset the high-pressure control, referring to the high-pressure connection instructions.
  • E
    Emily RyanAug 9, 2025
    Why does the compressor operate in short cycles in my Napoleon Air Conditioner?
    • M
      Michael GrahamAug 9, 2025
      If your Napoleon Air Conditioner compressor is operating in short cycles, it might be due to incorrect voltage. Ensure the voltage at the compressor terminals is within +/10% of the nameplate marking when the unit is running. A defective overload protector could also be the cause, so replace it and check for the correct voltage. Lastly, a refrigerant undercharge could be the issue, requiring you to add more refrigerant.
  • R
    ryoungAug 15, 2025
    What to do if my Napoleon 13 SEER Air Conditioner provides too little cooling?
    • A
      Andre JonesAug 15, 2025
      If your Napoleon Air Conditioner isn't cooling enough, it could be due to a low voltage condition, which can be addressed by adding start kit components. An improperly sized unit may also be the cause, requiring a recalculation of the load. Insufficient indoor airflow, which should be around 400 CFM per ton, could be another factor. Additionally, check for an incorrect refrigerant charge and follow the charging procedure in the installation manual. Lastly, the presence of air, non-condensables, or moisture in the system may necessitate refrigerant recovery.
  • H
    Heidi ColeAug 21, 2025
    What to do if outdoor fan is on but compressor is off in Napoleon 13 SEER Air Conditioner?
    • D
      Dr. Amber JohnsonAug 21, 2025
      If the outdoor fan is running but the compressor is off in your Napoleon Air Conditioner, a defective run or start capacitor might be the issue, requiring replacement. Similarly, a defective start relay should also be replaced. Check for correct voltage at the compressor and tighten all connections if there's a loose wire. If the compressor is stuck, grounded, has an open motor winding, or an open internal overload, wait at least 2 hours for the overload to reset; if it remains open, replace the compressor.
  • A
    April VasquezAug 27, 2025
    Why does my Napoleon 13 SEER have high head pressure and low suction pressure?
    • T
      Tonya GomezAug 27, 2025
      If your Napoleon Air Conditioner has high head pressure and low suction pressure, there might be a restriction in the liquid line, expansion device, or filter drier, which would require removing or replacing the defective component. Another cause could be insufficient indoor airflow; in this case, clean or check the filters, registers, or evaporator coil for any obstructions.

Summary

SAFETY

SAFETY RULES

Lists critical safety instructions for installation, service, and operation.

INSTALLATION

REFRIGERANT LINE SET INSTALLATION

Covers limitations, brazing, leak testing, and insulation for refrigerant lines.

EVACUATION

EVACUATE THE REFRIGERANT LINES AND INDOOR COIL

Step-by-step procedure for using a vacuum pump and micron gauge to evacuate the system.

SERVICE VALVES

ELECTRICAL

HIGH VOLTAGE

Covers power supply, disconnect switch, grounding, thermostat, and wiring diagram requirements.

START UP

SYSTEM CHARGE ADJUSTMENT

SYSTEM TOTAL CHARGE

Explains factory charge, refrigerant correction factors, and system charging principles.

CHECKOUT PROCEDURES

CHECKOUT PROCEDURE

Checklist for verifying unit condition, connections, and proper installation.

AIR CONDITIONING TROUBLESHOOTING

Napoleon 13 SEER Specifications

General IconGeneral
BrandNapoleon
Model13 SEER
CategoryAir Conditioner
LanguageEnglish