Do you have a question about the Naterial ANEMO ZN DC116 and is the answer not in the manual?
Never attempt to disassemble or repair the wind sensor or awning; consult a qualified technician for assistance.
Follow all safety instructions to avoid injury and damage. Keep manual for future use and use only as intended.
Maintain 0.4m clearance. Switch power off, remove excess cord, and disable unused equipment before installation.
Incorporate disconnection means in wiring per rules. Ensure proper tools, space, and a clean dry area for installation.
Choose a safe location. Non-professionals can install if instructions are followed; seek qualified help if needed.
Be careful with your fingers during the installation process to prevent injuries.
Ensure setup complies with NCF 15-100 standard. Always switch off current before any setup or connection operation.
Hardware not provided includes a waterproof junction box (P54) and cables for electrical connection.
Verify power supply voltage/current matches label. Install a readily accessible disconnect device in fixed wiring.
Do not attempt self-repair; only qualified personnel. Damaged cords must be replaced by manufacturer or agent.
For inspection or maintenance of electrical parts, reliably disconnect the external blind from the energy supply.
Max load for non-retractable part is 800Pa. Actuating member must be accessible from a height lower than 1.3m.
Do not modify the appliance. Never open the electronic command box as it voids the warranty.
Use only original parts/accessories. Adapt fixing to the type of wall; non-recommended accessories can be risky.
Avoid high temperatures (e.g., near furnaces) and frosty conditions, which may damage the wind sensor.
Never use a damaged appliance. Disconnect power and contact supplier if damaged. Store transmitter indoors.
Details include Supply Voltage 230V~50Hz, Nominal power 0.3W, Protection class IP44, and 433MHz transmitter frequency.
Product complies with WEEE directive for separate collection and sorting of electronic waste to minimize environmental impact.
Declares the Wireless wind sensor, Model DC116, meets requirements of Radio Equipment and RoHS directives.
Lists specific norms and standards (Draft EN 301 489, EN300 220, EN 62479, EN 60730, EN 62321 series) met by the product.
Illustrates the circuit installation for the wind sensor, showing connections for Neutral and Phase.
Details the buttons and indicators on the DC116 unit, including wind grade, light grade, upward, setting buttons, and LED.
Specifies minimum clearance distances (0.5m, 0.1m, 2M) for optimal installation of the wind sensor.
Instructions on how to adjust the installation site by loosening and tightening mounting screws after opening the junction box.
Describes how the awning opens in breeze and closes in gale, and the wind grade references for different wind speeds.
Procedure to replace a wind sensor and match it with the remote controller using specific button presses.
| Wind speed measurement range | 0.3 - 30 m/s |
|---|---|
| Resolution | 0.1 m/s |
| Temperature measurement accuracy | ±2°C |
| Display | LCD |
| Data Hold | Yes |
| Max/Avg/Current Measurement | Yes |
| Auto Power Off | Yes |
| Type | Anemometer |
| Wind speed measurement accuracy | ±5% |
| Units | m/s, km/h, ft/min, knots, °C, °F |
Loading...