Why is my National Flooring Equipment Other showing reduced performance?
- XxlewisAug 4, 2025
Reduced performance in your National Flooring Equipment Other could stem from several causes. The blast wheel or control cage might be worn, requiring replacement. Check and adjust the belt tension. Ensure the valve closes properly; if not, close the valve, stop the motor, and readjust the valve. Make sure the motor reaches maximum speed before opening the valve to avoid admitting too much abrasive. Reduce the feed motion speed if it's too fast. Lastly, verify the motor's rotation direction; if incorrect, turn off control power, wait for the motor to stop, then switch the FWD/REV switch to the opposite position.